| 数据搜索系统,热门电子元器件搜索 |
|
3UG3501 数据表(PDF) 110 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 数据表(HTML) 110 Page - List of Unclassifed Manufacturers |
|
110 / 114 page ![]() 3TK28 Safety Relays With contactor relay enabling circuits 7/110 Siemens LV 1 T · 2006 ■Technical specifications 1) For instantaneous output. Type 3TK28 50 3TK28 51 3TK28 52 3TK28 53 3TK28 56 3TK28 57 Standards EN 60204-1 (VDE 0113 Part 1), EN ISO 12100, EN 954-1, IEC 61508 Category acc. to EN 954-1 3 3 3 4 As basic unit As basic unit Test certificates TÜV, UL, CSA Rated insulation voltage Ui • For control circuit V 50 • For output contacts V 690 • For pollution severity 3 Rated impulse withstand voltage Uimp • For control circuit V 500 • For output contacts kV 6 Coil operating range • AC operation 0.85 ... 1.1 × Us • DC operation 0.9 ... 1.15 × Us Coil ratings • DC/AC actuation at Us W 8.5 Rated operational currents Ie acc. to IEC 60947-5-1 • Ie / AC-15 at 230 V A 6 • Ie / DC-13 at 24 V A 10 (auxiliary switch blocks: 6) Short-circuit protection (Weld-free protection at IK = 1 kA) See Chapter 3, 3RH1 Contactor Relays, Technical specifications Mechanical endurance 30 million operating cycles Electrical endurance See Chapter 3, 3RH1 Contactor Relays, Characteristic curves Operating frequency z In operating cycles/h during normal duty 1/h 1000 Response time • Monitored start ms 200 200 200 60 -- -- • Autostart ms 300 300 300 60 -- -- Release time • For EMERGENCY-STOP ms 30 30 30 50 50 501)/ increments 0.05 ... 300 s • For supply failure ms 100 100 100 120 120 120 Recovery time • For EMERGENCY-STOP ms 20 20 20 500 500 500 • For supply failure s 0.02 0.02 0.02 7 7 7 Bridging of supply failures ms 5 5 5 5 5 5 Minimum command duration •EMERGENCY-STOP ms 20 20 20 30 • ON button ms 20 20 20 0.2 ... 5 s Simultaneity Conductor cross-sections Screw-type connection • Finely stranded with end sleeve mm2 2 × (0.25 ... 1), 1 × (0.25 ... 2.5) • Solid mm2 2 × (0.2 ... 1), 1 × (0.2 ... 2.5) • Tightening torque Nm 0.5 ... 0.6 Spring-loaded terminals (1 or 2 conductors can be connected) • Solid mm2 1 × (0.2 ... 2.5) • Finely stranded with end sleeve mm2 1 × (0.25 ... 2.5) • Finely stranded without end sleeve mm2 1 × (0.25 ... 2.5) • AWG conductors, solid or stranded 2 × AWG 24 ... 12 Permissible ambient temperature • During operation °C –25 ... +60 • During storage °C –40 ... +80 Degree of protection acc. to EN 60529 • Enclosures IP40 • Terminals IP20 Touch protection acc. to DIN VDE 0106 Part 100 Finger-safe Shock resistance •Sine wave g/ms 8/10 and 15/5 Permissible mounting position Any |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |