| 数据搜索系统,热门电子元器件搜索 |
|
3UG3501 数据表(PDF) 112 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
3UG3501 数据表(HTML) 112 Page - List of Unclassifed Manufacturers |
|
112 / 114 page ![]() Interface Converters 3RS17 interface converters 7/112 Siemens LV 1 T · 2006 ■Overview Interface converters perform the coupling function for analog signals on both the input side and the output side. They are indispensable when processing analog values with electronic controls. Under harsh industrial conditions in particular, it is often necessary to transmit analog signals over long distances. This means that electrical isolation is essential due to the different supply systems. The resistance of the wiring causes potential differences and losses which must be prevented. Electromagnetic disturbance and overvoltages can affect the signals on the input side in particular or even destroy the analog modules. All terminals of the 3RS17 interface converters are safe up to a voltage of 30 V DC and protected against switching poles. Short-circuit protection is an especially important function for the outputs. The devices are EMC-tested according to • EN 50081 (basic technical standard for emitted interference) • EN 61000-6-2 (basic technical standard for immunity to interference) The analog signals comply with • IEC 60381-1/2 ■Function Active interface converters Active interface converters provide maximum flexibility for the application by the use of an external supply voltage. Configuration with active interface converters is extremely easy because input and output resistances and voltage drops are compensated by the auxiliary supply. They support complete voltage isolation as well as conversion from one signal type to another or reinforcement. The load of the measured value transmitter is negligible. Passive interface converters Passive interface converters do not require an external supply voltage. This advantage can only be used by current signals that are converted 1:1. Reinforcement or conversion is not possible. The converters are used for complete electrical isolation of current signals and to protect the inputs and outputs. Passive isolators do not operate reaction-free, any load on the output produces an equal load on the input. When the passive converter is to be used, the output performance of the sensor and the input resistance of the analog input must be analyzed. This technique is being increasingly implemented in the case of pure current signals. Calculation guide for passive converters Note: Please note the following when using passive isolators: The current-driving voltage of the measuring transducer UE must be sufficient to drive the maximum current of 20 mA over the passive isolator with a voltage loss of UV = 2.7 V and the load RB. This means that: UB UE =2.7 V+20 mA × RB Distribution of the voltages in the case of passive isolators Input voltage depending on the load at Ia =20mA The following diagram shows the input voltage UE as a function of the load RB taking into account the voltage loss UV. If the load is known, the y-axis shows the minimum voltage that has to be supplied by the current source in order to drive the maximum current of 20 mA over the passive isolator and load. Current carrying capacity of the outputs A maximum output resistance is specified for current signals. This resistance value specifies how large the input resistance of the next device connected in series can be as a result of the power of the converter. For voltage signals, the maximum current that can be drawn from the output is the decisive factor. 2-way isolation In the case of 2-way isolation, the input is galvanically isolated from the output. The "null potential" of the supply voltage is the same as the reference potential for the analog output signal. 3-way isolation For the 3-path isolation, each circuit is electrically isolated from the other circuits, i.e. input, output, and supply voltage do not have a potential connection. 7 B 7 E 1 1 7 V = 2 , 7 V 4 B 1 1 N S B 0 1 3 1 2 a 7 0 2 , 7 5 1 0 N S B 0 1 3 1 3 a A / V 4 B / O 0 1 0 0 2 2 0 0 4 3 0 0 6 4 0 0 8 6 0 0 1 2 8 0 0 1 6 1 0 0 0 2 0 7 E / V 1 5 2 0 2 2 , 7 I N O U T V c c N S B 0 _ 0 1 3 1 4 a 2 - w a y i s o l a t i o n I N O U T V c c N S B 0 _ 0 1 3 4 3 3 - w a y i s o l a t i o n |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |