35 / 126 page ![]() DocID027870 Rev 1 35/126 STLUX I/O multifunction signal configuration 126 7 I/O multifunction signal configuration Several I/Os have multiple functionalities selectable through the configuration mechanism described from Section 7.1 to Section 7.5 on page 41. The STLUX I/Os are grouped into four different configurable ports: P0, P1, P2 and P3. 7.1 Multifunction configuration policy The STLUX supports either a cold or warm multifunction signal configuration policy according to the content of the EN_COLD_CFG bit field, a part of the GENCFG option byte register. When the EN_COLD_CFG bit is set, the cold configuration is selected and the multifunction signals are configured according to the values stored in the option bytes; otherwise when the EN_COLD_CFG bit is cleared (default case), the warm configuration mode is chosen and the multifunction pin functionality is configured through the miscellaneous registers. The configuration options and the proper configuration registers are detailed in Table 5: The warm configuration is volatile, thus not maintained after a device reset. 7.2 Port P0 I/O multifunction configuration signal The Port P0 multiplexes several input/output functionalities, increasing the device flexibility. The P0 port pins can be independently assigned to general purpose I/Os or to internal peripherals. All communication peripherals and the external oscillator are hosted by the Port P0 pins. In order to avoid electrical conflicts on the user application board, the P0 signals are configured at reset as GPIO0 inputs without pull-up resistors. Once the reset is released, the firmware application must initialize the inputs with the proper configuration according to the application needs. 7.2.1 Alternate function P0 configuration signals The multifunction pins can be configured via one of the following two registers, depending on the overall configuration policy (warm/cold): Cold configuration: AFR_IOMXP0 option byte registers (refer to Section 10: Option bytes on page 60). After the reset the P0 signals are configured in line with AFR_IOMXP0 contents. Warm configuration: MSC_IOMXP0 miscellaneous register (refer to Section 7.5 on page 41). After the reset, the P0 signals are configured as GPIO input lines with the pull-up disabled. Table 5. Multifunction configuration registers EN_COLD_CFG Configuration policy Multifunction configuration registers 1 Cold AFR_IOMXP0, AFR_IOMXP1 and AFR_IOMXP2 0 (default) Warm MSC_IOMXP0, MSC_IOMXP1 and MSC_IOMXP2 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |