数据搜索系统,热门电子元器件搜索
  Chinese  ▼
ALLDATASHEETCN.COM

X  

NET2890 数据表(PDF) 4 Page - List of Unclassifed Manufacturers

部件名 NET2890
功能描述  USB Interface Controller
PDF  73 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
制造商  ETC [List of Unclassifed Manufacturers]
网页  
标志 ETC - List of Unclassifed Manufacturers

NET2890 数据表(HTML) 4 Page - List of Unclassifed Manufacturers

  NET2890 Datasheet HTML 1Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 2Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 3Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 4Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 5Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 6Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 7Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 8Page - List of Unclassifed Manufacturers NET2890 Datasheet HTML 9Page - List of Unclassifed Manufacturers Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 73 page
background image
Specification
NET2890 USB Interface Controller
____________________________________________________________________________________
NetChip Technology, Inc., 1999
335 Pioneer Way, Mountain View, California 94041
TEL (650) 526-1490
FAX (650) 526-1494
http://www.netchip.com
Rev 2.0, Draft 9, July 16, 1999
4
4.9.3
Device-Remote Wake-Up ......................................................................................................33
4.9.4
Resume Interrupt................................................................................................................... 33
4.10
ROOT PORT RESET......................................................................................................................... 34
4.11
NET2890 POWER CONFIGURATION ............................................................................................... 34
4.11.1
Bus-Powered Device ............................................................................................................. 34
4.11.2
Self-Powered Device ............................................................................................................. 34
4.11.3
Low-Power Modes ................................................................................................................ 35
5.
CONFIGURATION REGISTERS .................................................................................................... 36
5.1
REGISTER DESCRIPTION ................................................................................................................. 36
5.2
REGISTER SUMMARY ..................................................................................................................... 36
5.2.1
Base registers (unpaged)....................................................................................................... 36
5.2.2
Endpoint / FIFO registers (paged) ....................................................................................... 37
5.2.3
Setup Packet registers (paged).............................................................................................. 37
5.2.4
Indexed registers ................................................................................................................... 38
5.3
BASE REGISTERS............................................................................................................................ 39
5.3.1
(Address 00h; PAGESEL) Paged Register Select ................................................................. 39
5.3.2
(Address 01h; MAINCTL) Main Control Register ................................................................ 39
5.3.3
(Address 02h; DMACTL) DMA Control Register ................................................................. 39
5.3.4
(Address 03h; IRQSTAT1) Interrupt Status Register 1 ......................................................... 40
5.3.5
(Address 04h; IRQSTAT2) Interrupt Status Register 2 ......................................................... 40
5.3.6
(Address 06h; IDXADDR) Index Register Address............................................................... 41
5.3.7
(Address 07h; IDXDATA) Indexed Register Data ................................................................ 41
5.3.8
(Address 0Bh; PKTLENLSB) Packet Length (LSB) .............................................................. 41
5.3.9
(Address 0Ch; PKTLENMSB) Packet Length (MSB)............................................................ 41
5.4
ENDPOINT / FIFO REGISTERS ........................................................................................................ 42
5.4.1
(Address 10h; EPCFG) Endpoint Configuration Register (one per Endpoint) .................... 42
5.4.2
(Address 11h; EPRSPSET) Endpoint Response Set Register (one per Endpoint) ................ 43
5.4.3
(Address 12h; EPRSPCLR) Endpoint Response Clear Register (one per Endpoint)............ 44
5.4.4
(Address 13h; EPIRQENB) Endpoint Interrupt Enable Register (one per Endpoint) .......... 45
5.4.5
(Address 14h; EPIRQSTAT) Endpoint Interrupt Status Register (one per Endpoint) .......... 45
5.4.6
(Address 15h; EPUSBSTAT) Endpoint USB Status Register (one per Endpoint)................. 46
5.4.7
(Address 16h; EPDOUT) Endpoint Data Out Register (one per Endpoint) ......................... 46
5.4.8
(Address 17h; EPDIN) Endpoint Data In Register (one per Endpoint)................................ 46
5.4.9
(Address 1Ah; FIFOCNT) FIFO Count Register (one per Endpoint)................................... 47
5.4.10
(Address 1Ch;FIFOCTL) FIFO Control Register (one per Endpoint) ................................. 47
5.4.11
(Address 1Eh;FIFOSTAT) FIFO Status Register (one per Endpoint) .................................. 47
5.5
SETUP REGISTERS .......................................................................................................................... 48
5.5.1
(Address 10h; SETUP0) Setup Byte 0 ................................................................................... 48
5.5.2
(Address 11h; SETUP1) Setup Byte 1 ................................................................................... 48
5.5.3
(Address 12h; SETUP2) Setup Byte 2 ................................................................................... 48
5.5.4
(Address 13h; SETUP3) Setup Byte 3 ................................................................................... 48
5.5.5
(Address 14h; SETUP4) Setup Byte 4 ................................................................................... 49
5.5.6
(Address 15h; SETUP5) Setup Byte 5 ................................................................................... 49
5.5.7
(Address 16h; SETUP6) Setup Byte 6 ................................................................................... 49
5.5.8
(Address 17h; SETUP7) Setup Byte 7 ................................................................................... 49
5.6
INDEXED REGISTERS...................................................................................................................... 50
5.6.1
(Index 00h; LOCALCTL) Local Bus Control ........................................................................ 50
5.6.2
(Index 01h; OURADDR) Our USB Address Register ........................................................... 50
5.6.3
(Index 02h; IRQENB1) Interrupt Enable Register 1............................................................. 50
5.6.4
(Index 03h; IRQENB2) Interrupt Enable Register 2............................................................. 51
5.6.5
(Index 07h; FRAMELSB) Frame Counter (LSB) .................................................................. 51
5.6.6
(Index 08h; FRAMEMSB) Frame Counter (MSB) ................................................................ 51
5.6.7
(Index 0Ch; DIAG) Diagnostic Register ............................................................................... 52



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com