| 数据搜索系统,热门电子元器件搜索 |
|
AD9957/PCBZ 数据表(PDF) 24 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9957/PCBZ 数据表(HTML) 24 Page - Analog Devices |
|
24 / 61 page ![]() AD9957 Data Sheet Rev. F | Page 24 of 61 Knowledge of the frequency response of the half-band filters is essential to understanding their impact on the spectral properties of the input signal. This is especially true when using the quad- rature modulator to upconvert a baseband signal containing complex data symbols that have been pulse shaped. Consider that a complex symbol is represented by a real (I) and an imaginary (Q) component, thus requiring two digital words to represent a single complex sample of the form I + jQ. The sample rate associated with a sequence of complex symbols is referred to as fSYMBOL. If pulse shaping is applied to the symbols, the sample rate must be increased by some integer factor, M (a consequence of the pulse shaping process). This new sample rate (fIQ) is related to the symbol rate by fIQ = MfSYMBOL where fIQ is the rate at which complex samples must be supplied to the input of the first half-band filter in both (I and Q) signal paths. This rate should not be confused with the rate at which data is supplied to the AD9957. Typically, pulse shaping is applied to the baseband symbols via a filter having a raised cosine response. In such cases, an excess bandwidth factor (α, 0 ≤ α ≤ 1) is used to modify the bandwidth of the data. For α = 0, the data bandwidth corresponds to fSYMBOL/2; for α = 1, the data bandwidth extends to fSYMBOL. Figure 36 shows the relationship between α, the bandwidth of the raised cosine response, and the response of the first half-band filter. f f f TYPICAL SPECTRUM OF A RANDOM SYMBOL SEQUENCE RAISED COSINE SPECTRAL MASK SAMPLE RATE FOR 2× OVERSAMPLED PULSE SHAPING INPUT SAMPLE RATE OF FIRST HALF-BAND FILTER HALF-BAND FILTER RESPONSE INPUT SAMPLE RATE OF FIRST HALF-BAND FILTER NYQUIST BAND WIDTH ½fSYMBOL fSYMBOL 2 fSYMBOL 3 fSYMBOL ½fSYMBOL 0.4 fIQ fIQ 2 fIQ ½fIQ fSYMBOL 2 fSYMBOL 4 fSYMBOL α = 1 α = 0 α = 0.5 Figure 36. Effect of the Excess Bandwidth Factor (α) The responses in Figure 36 reflect the specific case of M = 2 (the interpolation factor for the pulse shaping operation). Increasing Factor M shifts the location of the fIQ point on the half-band response portion of the diagram to the right, as it must remain aligned with the corresponding MfSYMBOL point on the frequency axis of the raised cosine spectral diagram. However, if fIQ shifts to the right, so does the half-band response, proportionally. The result is that the raised cosine spectral mask always lies within the flat portion (dc to 0.4 fIQ) of the pass band response of the first half-band filter, regardless of the choice of α so long as M > 2. Therefore, for M > 2, the first half-band filter has absolutely no negative impact on the spectrum of the baseband signal when raised cosine pulse shaping is employed. For the case of M = 2, a problem can arise. This is highlighted by the shaded area in the tail of the α = 1 trace on the raised cosine spectral mask diagram. Notice that this portion of the raised cosine spectral mask extends beyond the flat portion of the half-band response and causes unwanted amplitude and phase distortion as the signal passes through the first half-band filter. To avoid this, simply ensure that α ≤ 0.6 when M = 2. PROGRAMMABLE INTERPOLATING FILTER The programmable interpolator is implemented as a low-pass CCI filter. It is programmable by a 6-bit control word, giving a range of 2× to 63× interpolation. The programmable interpolator is bypassed when programmed for an interpolation factor of 1. When bypassed, power to the stage is removed and the inverse CCI filter is also bypassed, because its compensation is not needed. The output of the programmable interpolator is the data from the 4× interpolator further upsampled by the CCI filter, accord- ing to the rate chosen by the user. This results in the upsampling of the input data by a factor of 8× to 252× in steps of four. The transfer function of the CCI interpolating filter is ( ) ( ) 5 1 0 2 = ∑ − = − R k fk π j e f H (1) where R is the programmed interpolation factor, and f is the frequency normalized to fSYSCLK. Note that minimum R requirements exist depending on the mode and frequency of fSYSCLK. The minimum R setting is defined under the following conditions. QDUC Mode If fSYSCLK is between 500 MSPS to 1 GSPS, then the minimum R is 2. If fSYSCLK is less than 500 MSPS, then the minimum R is 1. BFI Mode If fSYSCLK is between 500 MSPS to 750 MSPS, then the minimum R is 3. If fSYSCLK is between 250 MSPS to 500 MSPS, then the minimum R is 2. If fSYSCLK is less than 250 MSPS, then the minimum R is 1. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |