45 / 59 page ![]() Data Sheet ADA4254 Rev. B | Page 45 of 59 DIGITAL ERROR REGISTER (DIGITAL_ERR) DETAILS Table 16. DIGITAL_ERR Register Details (Register 0x03) Bit Name Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Reserved CAL_BUSY SPI_CRC_ERR SPI_RW_ERR SPI_SCLK_CNT_ERR Reserved MM_CRC_ERR ROM_CRC_ERR Access Reserved R RW RW RW Reserved RW RW Reset Reserved 0 0 0 0 Reserved 0 0 Bit 6, CAL_BUSY—Calibration Busy (Read Only) CAL_BUSY indicates that the PGIA is undergoing a calibration and self trim operation. Until this flag is clear, the ADA4254 output is not accurate. Writing a 1 or 0 to CAL_BUSY has no effect. CAL_BUSY can be output on GPIO2 when GPIO2 is configured as an output using the corresponding GPIO_DIR bit and when the CAL_BUSY_OUT bit is set to 1. Bit 5, SPI_CRC_ERR—SPI CRC Error The SPI_CRC_ERR error flag indicates that an error occurred during SPI communication with the ADA4254. This error occurs when the user provided CRC does not match the ADA4254 CRC calculation. Clear this error flag by writing a 1 to the SPI_CRC_ERR bit. Bit 4, SPI_RW_ERR—SPI Read/Write Error The SPI_RW_ERR error flag indicates that a SPI read/write operation is attempted on an invalid address. This error flag can be cleared by writing a 1 to this bit. Bit 3, SPI_SCLK_CNT_ERR—SPI SCLK Count Error The SPI_SCLK_CNT_ERR error flag indicates that, during SPI communication while CS is low, the number of SCLK edges is either insufficient or excessive. This error flag can be cleared by writing a 1 to this bit. Bit 1, MM_CRC_ERR—Memory Map CRC Error The MM_CRC_ERR error flag indicates that the current internal memory map does not match the result from the previous SPI write. If this error occurs, it is recommended to reprogram the ADA4254 registers. This error flag can be cleared by writing a 1 to this bit. Bit 0, ROM_CRC_ERR—ROM CRC Error The ROM_CRC_ERR error flag indicates that the internal ROM did not pass the CRC check. If this error occurs, it is strongly recommended to reset or power cycle the device. If the error does not reset with a power cycle or a soft reset, it is possible that the device is permanently damaged. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |