36 / 66 page ![]() Data Sheet AD4052/AD4058 MODES OF OPERATION analog.com Rev. B | 36 of 66 Trigger Mode In trigger mode, threshold crossings trigger the AD4052/AD4058 to automatically perform a 16-bit conversion of the input signal and transition into sample mode. The corresponding alert signals and status bits are asserted to send an interrupt to the digital host. The host can then read the 16-bit result from the SPI as described in the sample mode section or from the MAX_SAMPLE_REG or MIN_SAMPLE_REG registers in configuration mode. Figure 62 shows a flowchart for register configuration, the com- parison sequence operations, and the behavior of the hardware interrupts and alert flags following threshold crossings in trigger mode. Table 16 lists the configuration register settings to select trigger mode. When a maximum or minimum crossing is detected, the MAX_INTR or MIN_INTR signal asserts, respectively. The internal timer is disabled to stop autonomous sampling, and the ADC core powers up to convert the input signal. Figure 64 shows a timing diagram for the threshold detection and ADC sampling in trigger mode. Following the threshold event, the firmware can either continue operating the AD4052/AD4058 in sample mode to perform more conversions, or the firmware can send the exit command to put the device into configuration mode and read the alert registers. The MAX_INTR and MIN_INTR signals hold their states until the host sends the exit command to transition to register mode. Note that following the transition to sample mode, the ADC_MODE bit field in the register map is internally overwritten to 2’h0 and must be rewritten to 2’h3 to reenter autonomous mode. The MAX_FLAG or MIN_FLAG bit is also asserted when MAX_INTR or MIN_INTR asserts, respectively. The MAX_FLAG and MIN_FLAG bits are sticky and do not clear until the host sets them to 1’b1 with a register write. It is recommended to reset the MAX_FLAG and MIN_FLAG bits after sending the exit command and before returning to autonomous mode. Figure 62. Trigger Mode Flowchart |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |