459 / 750 page ![]() Section 12 Serial Communication Interface Rev.6.00 Jun. 03, 2008 Page 411 of 698 REJ09B0074-0600 Table 12.11 SSR Status Flags and Receive Data Handling SSR Status Flag RDRF* ORER FER PER Receive Data Receive Error Type 1 1 0 0 Lost Overrun error 0 0 1 0 Transferred to RDR Framing error 0 0 0 1 Transferred to RDR Parity error 1 1 1 0 Lost Overrun error + framing error 1 1 0 1 Lost Overrun error + parity error 0 0 1 1 Transferred to RDR Framing error + parity error 1 1 1 1 Lost Overrun error + framing error + parity error Note: * The RDRF flag retains the state it had before data reception. Yes <End> [1] No Initialization Start reception [2] No Yes Read RDRF flag in SSR [4] [5] Clear RE bit in SCR to 0 Read ORER, PER, and FER flags in SSR Error processing (Continued on next page) [3] Read receive data in RDR, and clear RDRF flag in SSR to 0 No Yes PER ∨ FER ∨ ORER = 1 RDRF = 1 All data received? [1] SCI initialization: The RxD pin is automatically designated as the receive data input pin. [2] [3] Receive error processing and break detection: If a receive error occurs, read the ORER, PER, and FER flags in SSR to identify the error. After performing the appropriate error processing, ensure that the ORER, PER, and FER flags are all cleared to 0. Reception cannot be resumed if any of these flags are set to 1. In the case of a framing error, a break can be detected by reading the value of the input port corresponding to the RxD pin. [4] SCI status check and receive data read: Read SSR and check that RDRF = 1, then read the receive data in RDR and clear the RDRF flag to 0. Transition of the RDRF flag from 0 to 1 can also be identified by an RXI interrupt. [5] Serial reception continuation procedure: To continue serial reception, before the end bit for the current frame is received, reading the RDRF flag and RDR, and clearing the RDRF flag to 0 should be finished. The RDRF flag is cleared automatically when DMAC is activated by a reception complete interrupt (RXI) and the RDR value is read. Figure 12.12 Sample Serial Data Reception Flowchart (1) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |