477 / 750 page ![]() Section 12 Serial Communication Interface Rev.6.00 Jun. 03, 2008 Page 429 of 698 REJ09B0074-0600 bits in SCMR to 0. According to Smart Card regulations, clear the O/ E bit in SMR to 0 to select even parity mode. Ds AZ Z A A A Z AA A (Z) (Z) State D7 D6 D5 D4 D3 D2 D1 D0 Dp Figure 12.27 Inverse Convention (SDIR = SINV = O/ E = 1) With the inverse convention type, the logic 1 level corresponds to state A and the logic 0 level to state Z, and transfer is performed in MSB-first order. The start character data for the above is H'3F. For the inverse convention type, set the SDIR and SINV bits in SCMR to 1. According to Smart Card regulations, even parity mode is the logic 0 level of the parity bit, and corresponds to state Z. In this LSI, the SINV bit inverts only data bits D0 to D7. Therefore, set the O/ E bit in SMR to 1 to invert the parity bit for both transmission and reception. 12.7.3 Clock As a transmit/receive clock, only an internal clock which is generated by an on-chip baud rate generator can be used. When clock output is selected by setting CKE0 to 1, a clock with a frequency S times the bit rate is output from the SCK pin. Note: Symbol S is the value of S described in section 12.3.11, Bit Rate Register (BRR). 12.7.4 Block Transfer Mode Operation in block transfer mode is the same as that in the normal Smart Card interface mode, except for the following points. • In reception, though the parity check is performed, no error signal is output even if an error is detected. However, the PER bit in SSR is set to 1 and must be cleared before receiving the parity bit of the next frame. • In transmission, a guard time of at least 1 etu is left between the end of the parity bit and the start of the next frame. • In transmission, because retransmission is not performed, the TEND flag is set to 1, 11.5 etu after transmission start. • As with the normal Smart Card interface, the ERS flag indicates the error signal status, but since error signal transfer is not performed, this flag is always cleared to 0. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |