76 / 144 page ![]() ST72774/ST727754/ST72734 76/144 TIMING MEASUREMENT UNIT (Cont’d) – Obtain the minimum number of horizontal sync output pulses (V2) between the last fall- ing edge of the active video input (AV) and the rising edge of the vertical sync signal (VSYN- CO or VFBACK) during two 2 consecutive frames. The H_V bit selects horizontal or vertical measurement. This selection should be made prior to starting the measurement by setting the START bit. This bit is set by software but only cleared by hardware at the end of the measurement. When the measurement is finished (rising edge of AV, horizontal or vertical sync signals), the results (T1,T2) are transferred into the corresponding registers (H1,H2) or (V1,V2). Note: The values of the H1/H2 or V1/V2 registers are available only at the end of a measurement (after the START bit has been cleared). 4.5.3.1 Horizontal Measurement When the H_V bit = 1, and when the START bit is set by software, the measurement starts after the next vertical sync pulse. The TMU searches the minimum values of H1 and H2 until the rising edge of the next following vertical sync pulse. The START bit is then cleared by hardware. The values of the H1 and H2 registers are available only at the end of a measurement, in other words when the START bit is at 0. 4.5.3.2 Vertical Measurement When the H_V bit = 0 and, when the START bit is set by software, the TMU measures the minimum V1 and V2 values during 2 consecutive vertical frames. The START bit is then cleared by hardware. 4.5.3.3 Special cases – If an overflow of the counter occurs during any of the measurements, the measured T1 or T2 val- ues will be 7FFh. – If the AV signal is always low (no active video), the measured T1 or T2 values will also be 7FFh. – If T1 ≤ 0 (AV already high when the falling edge of the sync signal occurs), the measured T1 val- ue will be fixed to 1. – If T2 ≤ 0 (AV still high when the rising edge of the sync signal occurs), a specific T2 value will be re- turned. Note: Refer to Application Note AN1183 for further de- tails. Figure 48. Horizontal Measurement Figure 49. Vertical Measurement HSYNCO or AV H1 H2 H1 and H2 measured in oscillator clock periods Note: HSYNCO or HFBACK must be positive. HFBACK VSYNCO or AV V1 V2 V1 and V2 measured in horizontal pulses Note: VSYNCO or VFBACK must be positive. VFBACK |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |