| 数据搜索系统,热门电子元器件搜索 |
|
L6717ATR 数据表(PDF) 32 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6717ATR 数据表(HTML) 32 Page - STMicroelectronics |
|
32 / 57 page ![]() Power manager I2C L6717A 32/57 DocID024465 Rev 1 6.1.4 Droop function adjustment (DRP_ADJ) This command allows to adjust the slope for the output voltage load line once the external components are fixed by modifying the k DRP and k DRPNB parameters defined in Section 7.3 and Section 7.6. See Table 12 and Table 16 for details about the codification of the command and the data stream. 6.1.5 Power management flags This command allows to set several flags to configure L6717A power management. The flags allows to define: – PSI_A. This flag defines the strategy to adopt as a consequence of PSI_L assertion in the SVI command. It is possible to program the device to work in single phase (PSI_A = 0b - default) or two phase (PSI_A = 1b) when PSI_L is asserted through the SVI bus. The same strategy is used for DPM mode. See Section 5.4.3 for details about PSI management and light-load efficiency optimizations. See Section 6.2 for details about DPM. – PSI_EN. This flag defines whether to enable or not the PSI_L management. Default is to manage PSI_L flag assertion through SVI bus (PSI_EN = 1b). – DPM_ON. This flag defines whether to enable or not the DPM mode. The strategy adopted by DPM is defined through the PSI_A flag. See Section 6.2 for details about DPM. DPM is disabled by default (DPM_ON = 0h). – DPMTH. Allow to program up to 4 different strategies for DPM mode by properly adjusting the V DPM threshold. See Section 6.2 for details about DPM. See Table 12, Table 17 and Table 19 for details about the codification of the Command and the Data Stream. Table 15. FSW_ADJ command - switching frequency adjustment codification Data stream [6:8] Fsw adjustment Data stream [6:8] Fsw adjustment 000 Reset to frequency programmed by OSC 100 Reset to frequency programmed by OSC 001 -10% 101 +10% 010 -20% 110 +20% 011 Ignored 111 Ignored Table 16. DRP_ADJ command - droop function adjustment codification Data stream [5:6] and [7:8] DRP adjustment kDRP and kDRPNB 00 1/4 01 1/2 10 Droop disabled 11 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |