| 数据搜索系统,热门电子元器件搜索 |
|
L6717ATR 数据表(PDF) 42 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6717ATR 数据表(HTML) 42 Page - STMicroelectronics |
|
42 / 57 page ![]() Output voltage monitoring and protections L6717A 42/57 DocID024465 Rev 1 8 Output voltage monitoring and protections L6717A monitors the regulated voltage of both sections through pin VSEN and NB_VSEN in order to manage OV, UV and PWRGOOD. The device shows different thresholds when in different operative conditions but the behavior in response to a protection event is still the same as described below. Protections are active also during soft-start (See Section 7.8) while they are masked during OTF-VID transitions with an additional delay to avoid false triggering. 8.1 Programmable overvoltage (I2DIS = 3.3 V) When power manager I 2 C is disabled, L6717A provides the possibility to adjust OV threshold (common for both Sections) through the SDA/OVP pin. Connecting the pin to SGND through a resistor R OVP , the OVP threshold becomes the voltage present at the pin. Since the SDA/OVP pin sources a constant I OVP =10 μA current, the programmed over voltage threshold will be OVP TH =R OVP *10 μA. Table 21.L6717A protection at a glance L6717A Section CORE North bridge Overvoltage (OV) SVI / PVI: +250mV above reference, programmable by power manager I2C bus. I2CDIS = 3.3V: Programmable through SDA/OVP pin. V_FIX: Fixed to 1.8V. Action: IC latch; LS=ON & PWMx = 0 (if applicable); Other section (SVI only): HiZ; FLT driven high. Undervoltage (UV) VSEN, NB_VSEN = VID -400mV. Active after Ref > 500mV Action: IC latch; both sections HiZ; FLT driven high. PWRGOOD PWRGOOD is the logic AND between internal CORE and NB PGOOD in SVI mode while is the CORE section PGOOD in PVI mode. Each PGOOD is set to zero when the related voltage falls below the programmed reference -250mV. Action: Section(s) continue switching, PWRGOOD driven low. VSEN, NB_VSEN disconnection Set when VSEN > CS1N +600mV. Action: UV-Like Set when VSEN > NB_CSN +600mV. Action: UV-Like (SVI only) FBG, NB_FBG disconnection Internal comparator across the opamp to recover from GND losses. Action: UV-Like Overcurrent (OC) Current monitor across inductor DCR. Dual protection, per-phase and average. Action: UV-Like Current monitor across inductor DCR. Constant current. Action: UV-Like On-the-fly VID Protections masked with the exception of OC with additional 16 clock delay to prevent from false triggering (both SVI and PVI). |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |