| 数据搜索系统,热门电子元器件搜索 |
|
ADE75 数据表(PDF) 41 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADE75 数据表(HTML) 41 Page - Analog Devices |
|
41 / 148 page ![]() Preliminary Technical Data ADE75xx/ADE71xx Rev. PrE | Page 41 of 148 100 Gain = 16 4 Reserved 0 Reserved 3 CFSIGN_OPT 0 This bit defines where the CF change of sign, APSIGN or VARSIGN, detection is implemented. 0 Filtered power signal 1 On a per CF pulse basis 2 - 0 PGA1[2:0] 0 These bits define the current channel input gain [2:0] 000 Gain = 1 001 Gain = 2 010 Gain = 4 011 Gain = 8 100 Gain = 16 Table 35. CALMODE register (0x3D) Bit Location Bit Mnemonic Default Value Description 7 – 6 Reserved 0 These bits should be kept cleared for proper operation 5 - 4 SEL_I_CH[1:0]9 0 These bits define the current channel used for energy measurements [1:0] 00 Current channel automatically selected by the tampering condition 01 Current channel connected to IA 10 Current channel connected to IB 11 Current channel automatically selected by the tampering condition 3 V_CH_SHORT 0 Logic one short voltage channel to ground 2 I_CH_SHORT 0 Logic one short Current channels to ground 1 - 0 Reserved Table 36. Interrupt Status Register 1 SFR (MIRQSTL, 0xDC) Bit Location Interrupt Flag Description 7 ADEIRQFLAG This bit is set if any of the ADE status flags that are enabled to generate an ADE interrupt are set. This bit is automatically cleared when all of the enabled ADE status flags are cleared. 6 Reserved Reserved. 5 FAULTSIGN1 Logic one indicates that the Fault mode has changed according to the configuration of the ACCMODE register 4 VARSIGN10 Logic one indicates that the reactive power sign changed according to the configuration of ACCMODE register 3 APSIGN Logic one indicates that the active power sign changed according to the configuration of ACCMODE register 2 VANOLOAD Logic one indicates that an interrupt was caused by apparent power no-load detected. This interrupt is also used to reflect the part entering the IRMS No load mode. 1 RNOLOAD2 Logic one indicates that an interrupt was caused by reactive power no-load detected. 0 APNOLOAD Logic one indicates that an interrupt was caused by active power no-load detected. Table 37. Interrupt Status Register 2 SFR (MIRQSTM, 0xDD) Bit Location Interrupt Flag Description 9 This function is not available in ADE7566 and ADE7569 products. 10 This function is not available in ADE7566 and ADE7166 products. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |