109 / 271 page ![]() Rev.1.40 Oct 06, 2004 page 109 of 269 M306V2ME-XXXFP, M306V2EEFP Item Specification Transfer data format • Transfer data length: 8 bits Transfer clock • When internal clock is selected (bit 3 at addresses 03A016, 037816 = “0”) : fi/ 2(n+1) (Note 1) fi = f1, f8, f32 • When external clock is selected (bit 3 at addresses 03A016, 037816 = “1”) : Input from CLKi pin Transmission/reception control _______ _______ _______ _______ • CTS function/RTS function/CTS, RTS function chosen to be invalid Transmission start condition • To start transmission, the following requirements must be met: _ Transmit enable bit (bit 0 at addresses 03A516, 037D16) = “1” _ Transmit buffer empty flag (bit 1 at addresses 03A516, 037D16) = “0” _______ _______ _ When CTS function selected, CTS input level = “L” • Furthermore, if external clock is selected, the following requirements must also be met: _ CLKi polarity select bit (bit 6 at addresses 03A416, 037C16) = “0”: CLKi input level = “H” _ CLKi polarity select bit (bit 6 at addresses 03A416, 037C16) = “1”: CLKi input level = “L” Reception start condition • To start reception, the following requirements must be met: _ Receive enable bit (bit 2 at addresses 03A516, 037D16) = “1” _ Transmit enable bit (bit 0 at addresses 03A516, 037D16) = “1” _ Transmit buffer empty flag (bit 1 at addresses 03A516, 037D16) = “0” • Furthermore, if external clock is selected, the following requirements must also be met: _ CLKi polarity select bit (bit 6 at addresses 03A416, 037C16) = “0”: CLKi input level = “H” _ CLKi polarity select bit (bit 6 at addresses 03A416, 037C16) = “1”: CLKi input level = “L” • When transmitting _ Transmit interrupt cause select bit (bit 0 at address 03B016, bit 4 at address 037D16) = “0”: Interrupts requested when data transfer from UARTi transfer buffer register to UARTi transmit register is completed _ Transmit interrupt cause select bit (bit 0 at address 03B016, bit 4 at address 037D16) = “1”: Interrupts requested when data transmission from UARTi transfer register is completed • When receiving _ Interrupts requested when data transfer from UARTi receive register to UARTi receive buffer register is completed Error detection • Overrun error (Note 2) This error occurs when the next data is ready before contents of UARTi receive buffer register are read out 2.11.2 Clock Synchronous Serial I/O Mode The clock synchronous serial I/O mode uses a transfer clock to transmit and receive data. Tables 2.11.2 and 2.11.3 list the specifications of the clock synchronous serial I/O mode. Figures 2.11.15 and 2.11.16 show the UARTi transmit/receive mode register in clock synchronous serial I/O mode. Interrupt request generation timing Table 2.11.2 Specifications of clock synchronous serial I/O mode (1) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |