| 数据搜索系统,热门电子元器件搜索 |
|
BQ28Z560-R1 数据表(PDF) 17 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ28Z560-R1 数据表(HTML) 17 Page - Texas Instruments |
|
17 / 60 page ![]() bq28z560-R1 www.ti.com SLUSBD3 – APRIL 2013 4. The HOST_DISCONNECT (DSG FET OFF) subcommand—This feature is useful for the system to disable the discharge FET from the battery pack if it fails to authenticate. The conditions stated above are ignored if there is charge current flow (body diode protection). Gas Gauge Control of Charge FET Firmware Control of Charge FET for Protection The gas gauge firmware control of the charge FET is achieved by using the GPIO with external circuitry. Typically the COUT pin is high and so to override this, the GPIO pin transitions low and the CHG FET gate drive is pulled low to turn OFF the Charge FET. The output of the GPIO pin will be released once the fault condition is removed. The following parameters can be controlled through firmware (GPIO pin) providing the set thresholds are within the range of the hardware limits set by the protector. 1. BATHI—Overvoltage protection using COV settings. If the cell voltage exceeds the firmware setting the GPIO output transitions low to turn off the Charge FET. The Charge FET is turned back on once the cell voltage decays below the set hysteresis (GPIO output transitions high). 2. OCC condition—If the average current is greater than the set OCC current, the GPIO output transitions low to turn of the Charge FET. The Charge FET is turned back on once the average current decreases to the set level. 3. OTC condition—The CFET output will transition low if the charge current is flowing and the temperature is above the set OTC threshold or Charge Inhibit Temperature Hi. Alternatively, the CFET will not be allowed to turn ON if the temperature is above the set OTC or Charge Inhibit Temperature Hi thresholds and charge inhibit flag is set. The conditions stated above are ignored if there is discharge current flow (body diode protection). 4. Taper Current (TC) condition—This condition can also be used to turn OFF the Charge FET when the [ChgFetTerm]bit (Bit 2/0x04) in Operation Configuration C is set and the gauge detects primary charge termination. The CHG FET would turn ON once RSOC < TCA clear%. Zero Voltage Charging When the cell voltage is 0 V and if the charger voltage is above the minimum operating voltage for 0 V charging (1.2 V max), the COUT output transitions to a high level and charge current can flow. FET Control Protection Figure 6 shows an overview of the FET Control Protection operation. Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 17 Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |