| 数据搜索系统,热门电子元器件搜索 |
|
BQ28Z560-R1 数据表(PDF) 46 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ28Z560-R1 数据表(HTML) 46 Page - Texas Instruments |
|
46 / 60 page ![]() bq28z560-R1 SLUSBD3 – APRIL 2013 www.ti.com Because the gas gauge is dormant in HIBERNATE mode, the battery should not be charged or discharged in this mode, because any changes in battery charge status will not be measured. If necessary, the host equipment can draw a small current (generally infrequent and less than 1 mA, for purposes of low-level monitoring and updating); however, the corresponding charge drawn from the battery will not be logged by the gauge. Once the gauge exits to NORMAL mode, the algorithm re-establishes the correct battery capacity. If a charger is attached, the host should immediately take the gas gauge out of HIBERNATE mode before beginning to charge the battery. CAUTION Charging the battery in HIBERNATE mode results in a notable gauging error that will take several hours to correct. In the HDQ bus communication interface, the bus line, when in HIBERNATE mode, must always be pulled high with an external resistor, and not allowed to go low in this mode. If the bus line is pulled low, the system may need to go through a full reset by the battery pack being removed and re-inserted. This may be an issue for systems with embedded battery packs. Alternatively, disable HIBERNATE mode by setting the CLEAR HIBERNATE bit to 0. Another option is to set Hibernate I,V settings to 0 in DF commands. SHUTDOWN MODE The device enters SHUTDOWN mode if there is a BATLOW condition detected or power down of the system. The device can also disable SHUTDOWN by using the CLEAR_SHUTDOWN (0x0014) option. NOTE • A SHUTDOWN command should NOT be invoked if charger voltage is present. • Sending a SHUTDOWN command while charger voltage is present causes a 1–2 s time of DSG FET off, and may or may not cause a watchdog reset. (If current is ≤ 0 after the DSG FET is opened, it will attempt to shutdown and start a watchdog; otherwise, it will only clear the shutdown flag without a reset.) • The recommendation is to NOT send a SHUTDOWN command if charger voltage is present. Figure 8 shows an overview of the hardware controlled SHUTDOWN operation. 46 Submit Documentation Feedback Copyright © 2013, Texas Instruments Incorporated Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |