| 数据搜索系统,热门电子元器件搜索 |
|
BQ28Z560-R1 数据表(PDF) 25 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ28Z560-R1 数据表(HTML) 25 Page - Texas Instruments |
|
25 / 60 page ![]() bq28z560-R1 www.ti.com SLUSBD3 – APRIL 2013 The AtRate() value is a signed integer with negative values interpreted as a discharge current value. The AtRateTimeToEmpty() function returns the predicted operating time at the AtRate value of discharge. The default value for AtRate() is zero and will force AtRateTimeToEmpty() to return 65,535. Both the AtRate() and AtRateTimeToEmpty() commands should only be used in NORMAL mode. AtRateTimeToEmpty(): 0x04/0x05 This read-only function returns an unsigned integer value of the predicted remaining operating time if the battery is discharged at the AtRate() value in minutes with a range of 0 to 65,534. A value of 65,535 indicates AtRate() = 0. The gas gauge updates AtRateTimeToEmpty() within 1 s after the system sets the AtRate() value. The gas gauge automatically updates AtRateTimeToEmpty() based on the AtRate() value every 1 s. The AtRate() and AtRateTimeToEmpty() commands should only be used in NORMAL mode. Temperature(): 0x06/0x07 This read-only function returns an unsigned integer value of the battery temperature in units of 0.1K measured by the gas gauge. Voltage(): 0x08/0x09 This read-only function returns an unsigned integer value of the measured cell-pack voltage in mV with a range of 0 to 6000 mV. Flags(): 0x0a/0x0b This read-only function returns the contents of the gas-gauge status register, depicting the current operating status. Table 7. Flags Bit Definitions Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 High Byte OT OC BATHI BATLO CHG_INH ALRT FC CHG Low Byte OCVTAKEN ISD TDD CHGFET DSGFET SOC1 SOCF DSG These fault flags will only clear if the fault condition is removed: OT = Overtemperature in a Charge or Discharge condition is detected. True when set. OC = Overcurrent in a Charge or Discharge condition is detected. True when set. Battery High bit indicating a high battery voltage condition. Refer to the data flash BATTERY HIGH parameters for BATHI = threshold settings. Battery Low bit indicating a low battery voltage condition. Refer to the data flash BATTERY LOW parameters for BATLO = threshold settings. CHG_INH = Charge Inhibit indicates the temperature is outside the range [Charge Inhibit Temp Low, Charge Inhibit Temp High]. True when set. ALRT = Indicates there is an Alert in the system. True when set. Full-charged is detected. FC is set when charge termination is reached and FC Set% = –1 (see CHARGING AND FC = CHARGE TERMINATION INDICATION for details) or State of Charge is larger than FC Set% and FC Set% is not –1. True when set. CHG = (Fast) charging allowed. True when set. OCVTAKEN = Cleared on entry to RELAX mode and set to 1 when OCV measurement is performed in RELAX. ISD = Internal Short is detected. True when set. TDD = Tab Disconnect is detected. True when set. CHGFET= Indicates the state of the firmware CFET control. True when set to 1. DSGFET= Indicates the state of the firmware DFET control. True when set to 1. SOC1 = State-of-Charge-Threshold 1 (SOC1 Set) reached. True when set. SOCF = State-of-Charge-Threshold Final (SOCF Set %) reached. True when set. DSG = Discharging detected. True when set. Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 25 Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |