48 / 60 page ![]() bq28z560-R1 SLUSBD3 – APRIL 2013 www.ti.com OPERATIONAL MODES POWER CONTROL Reset Functions When the bq28z560-R1 detects a software reset ([RESET] bit of Control() initiated), it determines the type of reset and increments the corresponding counter. This information is accessible by issuing the command Control() function with the RESET_DATA subcommand. Wake-Up Comparator The wake up comparator is used to indicate a change in cell current while the bq28z560-R1 is in SLEEP mode. Pack Configuration uses bits [RSNS1–RSNS0] to set the sense resistor selection. Pack Configuration also uses the [IWAKE] bit to select one of two possible voltage threshold ranges for the given sense resistor selection. An internal interrupt is generated when the threshold is breached in either charge or discharge directions. Setting both [RSNS1] and [RSN0] to 0 disables this feature. Table 21. IWAKE Threshold Settings(1) RSNS1 RSNS0 IWAKE Vth (SRP–SRN) 0 0 0 Disabled 0 0 1 Disabled 0 1 0 +1.0 mV or –1.0 mV 0 1 1 +2.2 mV or –2.2 mV 1 0 0 +2.2 mV or –2.2 mV 1 0 1 +4.6 mV or –4.6 mV 1 1 0 +4.6 mV or –4.6 mV 1 1 1 +9.8 mV or –9.8 mV (1) The actual resistance value vs. the setting of the sense resistor is not important, only the actual voltage threshold when calculating the Configuration. The voltage thresholds are typical values under room temperature. Flash Updates Data flash can only be updated if Voltage() > Flash Update OK Voltage. Flash programming current can cause an increase in the LDO dropout. The mode of going from one state to another is as follows: NORMAL → SLEEP → FULLSLEEP, then from FULLSLEEP to either HIBERNATE or SHUTDOWN. Mode Enter Mode Exit Mode Comment Go into other modes like SLEEP, If ALL conditions are satisfied like In this mode, power consumption is FULLSLEEP, HIBERNATE, or NORMAL Average Current, Cell Voltage, and the highest. Measurements are taken SHUTDOWN if conditions are Temperature. and updated every 1 s. satisfied. SLEEP bit set = 1 in the Control Change SLEEP bit = 0 OR register AND AverageCurrent AverageCurrent measurement > Sleep The data is measured every 20 s to SLEEP measured is equal to Sleep current current value OR Current detected is reduce current consumption. value. above the IWAKE setting. From SLEEP mode if the WAIT_FULLSLEEP wait is The system exits the FULLSLEEP The wait time to enter FULLSLEEP programmed, this is the time the mode if there are any communication FULLSLEEP from SLEEP is 1 s to 240 s with the system must be in SLEEP mode commands set on the bus to the default at 15 s. before it can go to FULLSLEEP device. mode. 48 Submit Documentation Feedback Copyright © 2013, Texas Instruments Incorporated Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |