| 数据搜索系统,热门电子元器件搜索 |
|
BQ28Z560-R1 数据表(PDF) 33 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ28Z560-R1 数据表(HTML) 33 Page - Texas Instruments |
|
33 / 60 page ![]() bq28z560-R1 www.ti.com SLUSBD3 – APRIL 2013 Table 11. CONSTANT CURRENT Mode Used when LOAD Mode = 0 LoadSelect Value Current Mode Used Average discharge current from previous cycle. There is an internal register that records the average discharge current through each 0 entire discharge cycle. The previous average is stored in this register. 1(default) Present average discharge current. This is the average discharge current from the beginning of this discharge cycle until present time. 2 Average current: based off the AverageCurrent() 3 Current: based off of a low-pass-filtered version of AverageCurrent() ( τ = 14 s) 4 Design capacity / 5: C Rate based off of Design Capacity /5 or a C / 5 rate in mA 5 Use the value specified by AtRate() 6 Use the value in User_Rate-mA. This provides a completely user-configurable method. If LOAD mode = 1 (Constant Power), then the following options are available: Table 12. CONSTANT POWER Mode Used When LOAD Mode = 1 LoadSelect Value Power Mode Used Average discharge power from the previous cycle. There is an internal register that records the average discharge power through 0 (default) each entire discharge cycle. The previous average is stored in this register. Present average discharge power. This is the average discharge power from the beginning of this discharge cycle until the present 1 time. 2 Average current × voltage: based off the AverageCurrent() and Voltage() 3 Current × voltage: based off of a low-pass-filtered version of AverageCurrent() ( τ = 14 s) and Voltage() 4 Design energy / 5: C Rate based off of Design Energy /5 or a C / 5 rate in mA 5 Use the value specified by AtRate() 6 Use the value in User_Rate-mW/cW. This provides a completely user- configurable method. Reserve Cap-mAh Reserve Cap-mAh determines how much actual remaining capacity exists after reaching 0 RemainingCapacity(), before Terminate Voltage is reached. A loaded rate or no-load rate of compensation can be selected for Reserve Cap by setting the [RESCAP] bit in the Pack Configuration register. Reserve Cap-mWh/cWh Reserve Cap-mWh determines how much actual remaining capacity exists after reaching 0 AvailableEnergy(), before Terminate Voltage is reached. A loaded rate or no-load rate of compensation can be selected for Reserve Cap by setting the [RESCAP] bit in the Pack Configuration register. Design Energy Scale Design Energy Scale is used to select the scale/unit of a set of data flash parameters. The value of Design Energy Scale can be either 1 or 10 only. Table 13. Data Flash Parameter Scale/Unit-Based on Design Energy Scale Data Flash Design Energy Scale = 1 (default) Design Energy Scale = 10 Design Energy mWh cWh Reserve Capacity –mWh/cWh mWh cWh Avg Power Last Run mW cW User Rate-mW/cW mWh cWh T Rise No Scale Scaled by x10 Dsg Current Threshold This register is used as a threshold by many functions in the bq28z560-R1 to determine if actual discharge current is flowing into or out of the cell. The default for this register should be sufficient for most applications. This threshold should be set low enough to be below any normal application load current but high enough to prevent noise or drift from affecting the measurement. Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 33 Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |