| 数据搜索系统,热门电子元器件搜索 |
|
BQ28Z560-R1 数据表(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
BQ28Z560-R1 数据表(HTML) 22 Page - Texas Instruments |
|
22 / 60 page ![]() bq28z560-R1 SLUSBD3 – APRIL 2013 www.ti.com HDQIntEn = Status bit indicating the HDQ interrupt function is active. True when set. Default is 0. SHUTDOWN = Status bit indicating the bq28z560-R1 is in SHUTDOWN mode. True when set. Default is 0. HIBERNATE = Status bit indicating a request for entry into HIBERNATE from SLEEP mode has been issued. True when set. Default is 0. Control bit when set will put the bq28z560-R1 into the lower power state of SLEEP mode. It is not possible to monitor this bit. Status bit indicating the bq28z560-R1 is in FULLSLEEP mode. True when set. The state can be detected by monitoring FULLSLEEP = the power used by the bq28z560-R1 because any communication will automatically clear it. SLEEP = Status bit indicating the bq28z560-R1 is in SLEEP mode. True when set. LDMD = Status bit indicating the bq28z560-R1 Impedance Track algorithm using CONSTANT POWER mode. True when set. Default is 0 (CONSTANT CURRENT mode). RUP_DIS = Status bit indicating the bq28z560-R1 Ra table updates are disabled. True when set. VOK = Status bit indicating cell voltages are OK for Qmax updates. True when set. QEN = Status bit indicating the bq28z560-R1 Qmax updates are enabled. True when set. Control(): 0x00/0x01 Issuing a Control() command requires a subsequent 2-byte subcommand. These additional bytes specify the particular control function desired. The Control() command allows the system to control specific features of the bq28z560-R1 during normal operation and additional features when the device is in access modes, as described in Table 6. Table 6. Control() Subcommands CNTL FUNCTION CNTL DATA SEALED ACCESS DESCRIPTION SET_FULLSLEEP 0x0010 Yes Sets the [FULLSLEEP] bit in Control Status register to 1 SET_HIBERNATE 0x0011 Yes Forces CONTROL_STATUS [HIBERNATE] to 1 CLEAR_HIBERNATE 0x0012 Yes Forces CONTROL_STATUS [HIBERNATE] to 0 SET_SHUTDOWN 0x0013 Yes Forces CONTROL_STATUS [SHUTDOWN] to 1 CLEAR_SHUTDOWN 0x0014 Yes Forces CONTROL_STATUS [SHUTDOWN] to 0 HOST_DISCONNECT 0x0018 Yes Forces the DOUT pin low to disable discharge. HOST_CONNECT 0x0019 Yes Clears DSGFETOFF allowing DOUT to go high if no other conditions force it low DEVICE_TYPE: 0x0001 Instructs the gas gauge to return the device type to addresses 0x00/0x01. FW_VERSION: 0x0002 Instructs the gas gauge to return the firmware version to addresses 0x00/0x01. The bq28z560-R1 firmware version return is 0x0214. HW_VERSION: 0x0003 Instructs the gas gauge to return the hardware version to addresses 0x00/0x01. For bq28z560-R1, 0x0060 is returned. For a firmware upgrade from bq28z560-R1, 0x0000 or 0x0060 is returned. RESET_DATA: 0x0005 Instructs the gas gauge to return the number of resets performed to addresses 0x00/0x01. PREV_MACWRITE: 0x0007 Instructs the gas gauge to return the previous command written to addresses 0x00/0x01. The value returned is limited to less than 0x0020. CHEM_ID: 0x0008 Instructs the gas gauge to return the chemical identifier for the Impedance Track configuration to addresses 0x00/0x01. 22 Submit Documentation Feedback Copyright © 2013, Texas Instruments Incorporated Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |