49 / 60 page ![]() bq28z560-R1 www.ti.com SLUSBD3 – APRIL 2013 Mode Enter Mode Exit Mode Comment From FULLSLEEP mode, the The system exits this mode if the VBAT system will go into HIBERNATE > programmed threshold, mode if the load current decreases OR load current is > programmed Enters hibernation if VBAT range is to programmed value, threshold, 2.4 V to 3 V with a default at 2.55 V. HIBERNATE OR if the cell voltage falls below the OR communication activity is on the The load current threshold range is 0 programmed value, bus line, to 0.7 A with a default value of 8 mA. OR if the host sets the command in OR the host sets the command in MAC. MAC. From SLEEP mode, the system will Exit from this mode if there is bus In this mode, the VREG and DSG enter this mode if the VBAT < 2.4 V activity, FET are turned OFF and the system for a period longer than 24 ms and OR the load current detected is > SHUTDOWN will only wake up if the charger is the charger is not attached. The IWAKE, attached on the Pack+, Pack– system can also be put in OR the charger is connected to the terminals. SHUTDOWN mode through MAC. system. AUTOCALIBRATION The bq28z560-R1 provides an auto calibration feature that measures the voltage offset error across SRP and SRN from time-to-time as operating conditions change. It subtracts the resulting offset error from the normal sense resistor voltage, VSR, for maximum measurement accuracy. Auto calibration of the ADC begins on entry to SLEEP mode, except if Temperature() is ≤ 5°C or Temperature() ≥ 45°C. The gas gauge also performs a single offset when (1) the condition of AverageCurrent() ≤ 100 mA and (2) {cell voltage change since last offset calibration ≥ 256 mV} or {temperature change since last offset calibration is greater than 80°C for ≥ 60 s}. Capacity and current measurements continue at the last measured rate during the offset calibration when these measurements cannot be performed. If the battery voltage drops more than 32 mV during the offset calibration, the load current has likely increased considerably and the offset calibration will be aborted. Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 49 Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |