38 / 60 page ![]() bq28z560-R1 SLUSBD3 – APRIL 2013 www.ti.com SleepWakeChg = If set to 1 will accumulate the charge as if it was active for 10 s ( instead of 20 s). If set, the CHG FET is turned OFF on detecting primary charge termination. The CHG FET is allowed to turn ChgFetTerm = back ON again when RSOC < TCA Clear %. CFET_INIT= Sets initial state of CHG FET at reset condition. 0 = CHG FET OFF, 1 = CHG FET ON. DFET_INIT= Sets initial state of DSG FET at reset condition. 0 = DSG FET OFF, 1 = DSG FET ON. PIN12F1 PIN12F0 State 0 0 NC or HDQ (default) 0 1 CHG FET 1 0 Bat Alert 1 1 RSVD Battery Alert Default Configuration Register When the system is configured as an interrupt indication, the bq28z560-R1 allows settings to be configured based on which faults are OR'ed for indication on the Alert output Table 18. This register is programmed/read via the methods described in ACCESSING THE DATA FLASH. The register is located at subclass = 64, offset = 4. Table 18. Battery Alert Default Configuration Bit Definition Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 UTC_EN UTD_EN RSVD RSVD RSVD RSVD RSVD RSVD Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 OTC_EN OTD_EN BH_EN BL_EN RSVD SOC1_EN OCC_EN OCD_EN UTC_EN = Allows detection of Under Temperature Charging when set to 1. Default is 0. UTD_EM = Allows detection of Under Temperature Discharging when set to 1. Default is 0. RSVD = Reserved. Default = 0. OTC_EN = Allows detection of Over Temperature Charging when set to 1. Default is 0. OTD_EN = Allows detection of Over Temperature Discharging when set to 1. Default is 0. BH_EN = Allows detection of Battery High when set to 1. Default is 0. BL_EN = Allows detection of Battery Low when set to 1. Default is 0. RSVD = Reserved. Default = 0. SOC1_EN Allows detection of SOC low when set to 1. Default is 0. OCC_EN = Allows detection of Overcurrent in CHARGE mode when set to 1. Default is 0. OCD_EN = Allows detection of Over Current in Discharge mode when set to 1. Default is 0. NOTE Important: The enable flags (Bits 7 to 4) are the reset values. Changing the data flash will not take effect until the gas gauge is re-started. Read/Write of the BatAlert_Configuration I2C data controls the runtime alert mask. MANUFACTURER INFORMATION BLOCKS The bq28z560-R1 contains 64 bytes of user-programmable data flash storage: Manufacturer Info Block A and Manufacturer Info Block B. The method for accessing these memory locations is slightly different, depending on whether the device is in UNSEALED or SEALED modes. When in UNSEALED mode and when and 0x00 has been written to BlockDataControl(), accessing the Manufacturer Info Blocks is identical to accessing general data flash locations. First, a DataFlashClass() command is used to set the subclass, then a DataFlashBlock() command sets the offset for the first data flash address within the subclass. The BlockData() command codes contain the referenced data flash data. When writing the data flash, a checksum is expected to be received by BlockDataChecksum(). Only when the checksum is received and verified is the data actually written to data flash. 38 Submit Documentation Feedback Copyright © 2013, Texas Instruments Incorporated Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |