37 / 60 page ![]() bq28z560-R1 www.ti.com SLUSBD3 – APRIL 2013 RESCAP = No-load rate of compensation is applied to the reserve capacity calculation. True when set. Default is 0. CalEn = bq28z560-R1 CALIBRATION mode is enabled. Default is 0. RSVD = Reserved. Default = 0 RSVD = Reserved. Default = 0. RSVD = Reserved. Default = 0. GNDSEL = The ADC ground select control. The VSS (Pin 6) is selected as ground reference when the bit is clear. Pin 7 is selected when the bit is set. Default is 0. IWAKE/RSNS1/RSNS0 = These bits configure the current wake function. Default is 0/0/1. GNDSEL = The ADC ground select control. The VSS (Pin 6) is selected as ground reference when the bit is clear. Pin 7 is selected when the bit is set. Default is 0. ResFactStep = Enables Ra step up/down to Max/Min Res Factor before disabling Ra updates. Default is 1. SLEEP = The gas gauge can enter sleep, if operating conditions allow. True when set. Default is 1. RMFCC = RM is updated with the value from FCC, on valid charge termination. True when set. Default is 1. CLR_READ = Clear on Read the Fault Flag register. True when set. Default = 0. ALRT_POL = Set polarity of Alert output. Set to 1 means active high, so any faults detected will change output from low to high. Default = 0, which means any fault detected will change output from high to low. RSVD = Reserved. Default = 0. TEMPS = Selects external thermistor for Temperature() measurements. True when set. Default is 1. Pack Configuration B Register Some bq28z560-R1 pins are configured via the Pack Configuration B data flash register, as indicated in Table 16. This register is programmed/read via the methods described in ACCESSING THE DATA FLASH. The register is located at subclass = 64, offset = 2. Table 16. Pack Configuration B Bit Definition Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ChgDoDEoC SE_TDD VconsEN SE_ISD JEITA LFPRelax DoDWT FConvEn ChgDoDEoC = Enable DoD at EoC during charging only. True when set. Default is 1. Default setting is recommended. SE_TDD = Enable Tab Disconnection Detection. True when set. Default is 1. VconsEN = Enable voltage consistency check. True when set. Default is 1. Default setting is recommended. SE_ISD = Enable Internal Short Detection. True when set. Default is 1. JEITA = Enable JEITA Temperature Charging function. True when set. Default is 1. LFPRelax = Enable LiFePO4 long RELAX mode when chemical ID 400 series is selected. True when set. Default is 1. DoDWT = Enable Dod weighting for LiFePO4 support when chemical ID 400 series is selected. True when set. Default is 1. FConvEn = Enable fast convergence algorithm. Default is 1. Default setting is recommended. Pack Configuration C Register Some bq28z560-R1 algorithm settings are configured via the Pack Configuration C data flash register, as indicated in Table 17. This register is programmed/read via the methods described in ACCESSING THE DATA FLASH. The register is located at subclass = 64, offset = 3. Table 17. Pack Configuration C Bit Definition Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 RSVD RSVDSBS PIN12F1 PIN12F0 SleepWakeChg ChgFetTerm CFET_INIT DFET_INIT RSVD = Reserved. Default = 0. RSVDSBS = Reserved for SBS command set. True when set. Default is 0. PIN12F1 = In combination with PIN12F0 will set the operation mode of pin 12 (see below). PIN12F0 = In combination with PIN12F1 will set the operation mode of pin 12 (see below). Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 37 Product Folder Links: bq28z560-R1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |