| 数据搜索系统,热门电子元器件搜索 |
|
AR8327-AL1A-R 数据表(PDF) 96 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
AR8327-AL1A-R 数据表(HTML) 96 Page - List of Unclassifed Manufacturers |
|
96 / 394 page ![]() 96 • AR8327/AR8327N Seven-port Gigabit Ethernet Switch Atheros Communications, Inc. 96 • June 2011 COMPANY CONFIDENTIAL 20 R/W 0 TCP_XMASSCAN_DROP_EN 1'b1: frame with Seq_Num=0, FIN=1, URG=1, and PSH=1 should be dropped 19 R/O 0 TCP_SYN1_ACK1_PSH1_DROP_ EN 1'b1: frame with SYN=1 & ACK=1 & PSH=1 should be dropped. 18 R/O 0 TCP_SYN1_PSH1_DROP_EN 1'b1: frame with SYN=1 & PSH=1 should be dropped. 17 R/O 0 TCP_SYN1_URG1_DROP_EN 1'b1: frame with SYN=1 & URG=1 should be dropped. 16 R/O 0 TCP_SYN_ERR_DROP_EN 1'b1:frame with SYN=1 & ACK=0 & SP<1024,should be dropped 15 R/O 0 TCP_HDR_MIN_DROP_EN 1'b1: if frame with TCP header length less than TCP_HDR_MIN_SIZE, but not first of fragment, should be dropped 14 R/W 0 TCP_SAME_PORT_DROP_EN 1'b1: TCP frame with SP equal to DP should be dropped. 13 R/W 0 IPV4_CHECKSUM_DROP_EN 1'b1: frame with ipv4 checksum error should be dropped. 12 R/W 0 IPV4_DIP_ERR_DROP_EN 1'b1: frame should be dropped if with DIP all zero,or DIP[31:24] is 0x7F. 11 R/W 0 IPV4_SIP_ERR_DROP_EN 1'b1: frame should be dropped if with SIP[31:24] more than 0xE0 and less than 0xF0, or equal to 0x7F, or SIP[31:0] is 0x32'hFFFFFFFF. 10 R/W 0 IPV4_FRAG_LEN_DROP_EN 1'b1: frame with ipv4 fragment length check error should be dropped. 9 R/W 0 IPV4_FRAG_MAX_DROP_EN 8 R/W 0 IPV4_FRAG_MIN_DROP_EN 1'b1: frame with offset length less than min should be dropped 7 R/W 0 IPV4_DF_DROP_EN 1'b1: frame with DF=1 and offset or MF not zero, should be dropped 6 R/W 0 IP_LEN_DROP_EN 1'b1: frame with ip length field error should be drop? include ipv4 and ipv6 5 R/W 0 IPV4_HDR_LEN_CHECK_EN 1'b1 :Check the IP options. If Frame is with options, drop or send to cpu 4 R/W 0 IPV4_HDR_LEN_ DROP_EN This bit can be used to forward or drop frame when ipv4 header length check fail. 3 R/O 0 IPV4_HDR_LEN_MIN_DROP_E N 1'b0:frame with ipv4 header length check error should be sent to cpu port(only to cpu port) 2 R/W 0 IP_SAME_PORT_DROP_EN 1'b1: frame with ipv4 header length check error should be drop Bit R/W Inital Value Mnemonic Description |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |