| 数据搜索系统,热门电子元器件搜索 |
|
AR8327-AL1A-R 数据表(PDF) 37 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
AR8327-AL1A-R 数据表(HTML) 37 Page - List of Unclassifed Manufacturers |
|
37 / 394 page ![]() Atheros Communications, Inc. AR8327/AR8327N Seven-port Gigabit Ethernet Switch • 37 2.9 LED Control There are totally 6 Led control rules. Three of them are used to control the LEDs of PHY 0 to PHY 3. The others are used to control the LEDs of PHY4. Each port has 3 LEDs, the default behavior of the LEDs are 1000_link_activity, 100_link_activity and 10_link_activity. The LED output is open-drain output type. So two or three of them can be connected together to indicate OR operation of the original LEDs. To achieve this operation, another way is to modify the LED control register. These LEDs also can be individually configured on or off by register. Each LED can be controlled by 16-bits shown in the following table. Table 2-21. LED Control Bit Name Description 15:14 PATTERN_EN 2’b00: LED always off 2’b01: LED blinking at 4 Hz 2’b10: LED always on 2’b11: LED controlled by the following bits 13 FULL_LIGHT_EN 1’b1: LED will light when link up in full-duplex 12 HALF_LIGHT_EN 1’b1: LED will light when link up at half-duplex 11 POWER_ON_LIGHT_EN 1’b1: module should enter POWER_ON_RESET status after reset. 10 LINK_1000M_LIGHT_EN 1’b1: LED will light when link up at 1000 Mbps 9 LINK_100M_LIGHT_EN 1’b1: LED will light when link up at 100 Mbps 8 LINK_10M_LIGHT_EN 1’b1: LED will light when link up at 10 Mbps 7 COL_BLINK_EN 1’b1: LED will blink when collision is detected 6 Reserved Must be 1’b0 5 RX_BLINK_EN 1’b1: LED will blink when receiving frame 4 TX_BLINK_EN 1’b1: LED will blink when transmitting frame 3 Reserved Must be 1’b0 2 LINKUP_OVER_EN 1’b1: RX/TX blinking should check with LINKUP speed, LINKUP LED is ON, allow blinking. Otherwise, OFF 1’b0: RX/TX blinking will ignore the LINKUP speed. 1:0 LED_BLINK_FREQ LED blink frequency select 2’b00: 2 HZ 2’b01: 4 Hz 2’b10: 8 Hz 2’b11: if link up at 1000Mbps, 8 Hz if link up at 100Mbps, use 4 Hz if link up at 10 Mbps, use 2 Hz Table 2-22. LED Rule Default Value Bit Name LED_RULE_0/1 LED_RULE_2/3 LED_RULE_4/5 Default Value 0xCC35 0xCA35 0xC935 15:14 PATTERN_EN 2’b11 2’b11 2’b11 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |