Back Button H8S/2225 Datasheet HTML 729Page - Renesas Technology Corp H8S/2225 Datasheet HTML 730Page - Renesas Technology Corp H8S/2225 Datasheet HTML 731Page - Renesas Technology Corp H8S/2225 Datasheet HTML 732Page - Renesas Technology Corp H8S/2225 Datasheet HTML 733Page - Renesas Technology Corp H8S/2225 Datasheet HTML 734Page - Renesas Technology Corp H8S/2225 Datasheet HTML 735Page - Renesas Technology Corp H8S/2225 Datasheet HTML 736Page - Renesas Technology Corp H8S/2225 Datasheet HTML 737Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 733 / 1071 page
background image
Section 16 I
2C Bus Interface (IIC) (Option)
Rev. 5.00 Aug 08, 2006 page 647 of 982
REJ09B0054-0500
Bit
Bit Name
Initial
Value
R/W
Description
0
SCP
1
W
Start Condition/Stop Condition Prohibit bit
The SCP bit controls the issue of start/stop conditions in
master mode.
To issue a start condition, write 1 in BBSY and 0 in SCP. A
retransmit start condition is issued in the same way. To issue
a stop condition, write 0 in BBSY and 0 in SCP. This bit is
always read as 1. If 1 is written, the data is not stored.
When, with the I2C bus format selected, IRIC is set to 1 and an interrupt is generated, other flags
must be checked in order to identify the source that set IRIC to 1. Although each source has a
corresponding flag, caution is needed at the end of a transfer.
When the TDRE or RDRF internal flag is set, the readable IRTR flag may or may not be set. Even
when data transfer is complete, the DTC activation request flag, IRTR, is not set until a
retransmission start condition or stop condition is detected after a slave address (SVA) or general
call address matched in the I2C bus format slave mode.
Even when the IRIC flag and IRTR flag are set, the TDRE or RDRF internal flag may not be set.
For a continuous transfer using the DTC, the IRIC or IRTR flag is not cleared at the completion of
the specified number of times of transfers. On the other hand, the TDRE and RDRF flags are
cleared because the specified number of times of read/write operations have been complete.
Table 16.4 shows the relationship between the flags and the transfer states.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com