124 / 261 page ![]() 124 Am79C978 8 MREINTE PHY Management Read Error In- terrupt Enable. If MREINTE is set, the MREINT bit will be able to set the INTR bit. This bit is always read/write ac- cessible. MREINTE is set to 0 by H_RESET and is not affected by S_RESET or setting the STOP bit 7 MAPINT PHY Management Auto-Poll In- terrupt. The PHY Auto-Poll inter- rupt is set by the Am79C978 controller to indicate that the cur- rently read status does not match the stored previous status indi- cating a change in state for the in- ternal PHY. A change in the Auto- Poll Access Method (BCR32, Bit 11) will reset the shadow register and will not cause an interrupt on the first access from the Auto-Poll section. Subsequent accesses will generate an interrupt if the shadow register and the read register produce differences. When MAPINT is set to 1, INTA is asserted if the enable bit MAP- INTE is set to 1. This bit is always read/write ac- cessible. MAPINT is cleared by the host by writing a 1. Writing a 0 has no effect. MAPINT is cleared by H_RESET and is not affected by S_RESET or setting the STOP bit. 6 MAPINTE PHY Auto-Poll Interrupt Enable. If MAPINTE is set, the MAPINT bit will be able to set the INTR bit. This bit is always read/write ac- cessible. MAPINTE is set to 0 by H_RESET and is not affected by S_RESET or setting the STOP bit. 5 MCCINT PHY Management Command Complete Interrupt. The PHY Management Command Com- plete Interrupt is set by the Am79C978 controller when a read or write operation to the in- ternal PHY Data Port (BCR34) is complete. When MCCINT is set to 1, INTA is asserted if the enable bit MC- CINTE is set to 1. This bit is always read/write ac- cessible. MCCINT is cleared by the host by writing a 1. Writing a 0 has no effect. MCCINT is cleared by H_RESET and is not affected by S_RESET or setting the STOP bit. 4 MCCINTE PHY Management Command Complete Interrupt Enable. If MCCINTE is set to 1, the MC- CINT bit will be able to set the INTR bit when the host reads or writes to the internal PHY Data Port (BCR34) only. Internal PHY Management Commands will not generate an interrupt. For in- stance Auto-Poll state machine generated management frames will not generate an interrupt upon completion unless there is a compare error which gets report- ed through the MAPINT (CSR7, bit 6) interrupt or the MCCIINTE is set to 1. This bit is always read/write ac- cessible. MCCINTE is set to 0 by H_RESET and is not affected by S_RESET or setting the STOP bit. 3 MCCIINT PHY Management Command Complete Internal Interrupt. The PHY Management Command Complete Interrupt is set by the Am79C978 controller when a read or write operation on the in- ternal PHY management port is complete from an internal opera- tion. Examples of internal opera- tions are Auto-Poll or PHY Management Port generated management frames. These are normally hidden to the host. When MCCIINT is set to 1, INTA is asserted if the enable bit MC- CINTE is set to 1. This bit is always read/write ac- cessible. MCCIINT is cleared by the host by writing a 1. Writing a 0 has no effect. MCCIINT is cleared by H_RESET and is not |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |