38 / 128 page ![]() ADP5140 Data Sheet Rev. 0 | Page 38 of 128 FBx FAULT HIGH THRESHOLD FBx WARNING HIGH THRESHOLD FBx WARNING LOW THRESHOLD FBx FAULT LOW THRESHOLD FBx TYPICAL VALUE HYSTERESIS HYSTERESIS HYSTERESIS HYSTERESIS FBx RISING FBx FALLING NO WARNING NO WARNING WARNING WARNING WARNING FAULT NO FAULT NO FAULT FAULT FAULT FAULT WINDOW WARNING WINDOW WARNING WINDOW FAULT WINDOW Figure 81. FBx Voltage Window Comparator If the voltage on the FBx pin is outside of the warning window, the regulator still functions and sets the corresponding warning bit in the WARN_STATUS register and WARN_LATCH register. If the voltage on the FBx pin is lower than the fault low threshold, the regulator still functions and sets the corresponding x_UV_STATUS bit in the UV_STATUS register and UV_LATCH register. If the voltage on the FBx pin is higher than the fault high threshold, the regulator turns off and sets the corresponding x_OV_STATUS bit in the OV_STATUS register and OV_LATCH register. The warning window and fault window are programmable through the FBx_WARN_WINDOW and FBx_FAULT_ WINDOW bits in the WARN_WINDOW and FAULT_ WINDOW SPI registers. The programmable range is from 4% to 8%, as shown in Table 21 and Table 22, with a fixed hysteresis. These threshold windows are referenced to the normal output voltage on the power rail. See Table 1 for the detailed specification. Table 21. FBx Voltage Monitor Warning Window FBx_WARN_WINDOW, Bits[1:0] Warning Window (%) 00 4 01 (Default) 5 10 6 11 8 Table 22. FBx Voltage Monitor Fault Window FBx_FAULT_WINDOW, Bits[1:0] Fault Window (%) 00 4 01 5 10 (Default) 6 11 8 The blank time of the FBx voltage monitor is programmable through the FBx_BLANK_TIME bits in the VOLTAGE_ BLANK_TIME0 and VOLTAGE_BLANK_TIME1 SPI registers. The programmable range is from 16 µs to 352 µs, as shown in Table 23. Table 23. Voltage Monitor Blank Time FBx_BLANK_TIME, Bits[3:0] Blank Time (µs) 0000 16 0001 32 0010 (Default) 48 0011 64 0100 80 0101 96 0110 112 0111 128 1000 144 1001 160 1010 176 1011 192 1100 208 1101 240 1110 288 1111 352 VMx VOLTAGE SUPERVISOR The ADP5140 integrates two voltage supervisors, VM0 and VM1. The VMx voltage supervisors monitor the voltage added on the VMx pin and compare the voltage with the internal 600 mV reference voltage. The voltage monitor function of VMx is disabled by default and can be enabled as a single overvoltage or undervoltage monitor or window monitor according to the VMx_TYP bits settings in the VM_TYP_CONFIGURATION register. The reference of VMx is derived from an independent band gap powered by the AVDD pin. When VMx is configured as a window monitor, and the voltage on the VMx pin is out of the monitoring window, a warning or fault event is reported in the WARN_STATUS, OV_STATUS, and UV_STATUS registers, and the relevant latch bits in the WARN_LATCH, OV_LATCH, and UV_LATCH registers are set. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |