| 数据搜索系统,热门电子元器件搜索 |
|
ST52T301 数据表(PDF) 51 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST52T301 数据表(HTML) 51 Page - STMicroelectronics |
|
51 / 100 page ![]() with inductive load (i.e. universal or monophase motors). In the figure 10.8 is shown the relation between the Phase Angle α and the Current flow angle γ . The peripheral allows to control the Phase Angle or equivalently the time T1 (see Figure 10.9). It is possibleto changeTime T1 settingthe contents of the peripheral register PERIPH_REG_1. This value could be directly loaded by using one of the two fuzzy outputs or by using a value coming from the Registers File, according with INPSL and FZSL configurationbits of REG_CONF12 (seeTable 10.6 and Figure 10.13). In order to synchronizethe peripheral with the zero crossing of the main voltage the two pins MAIN1 and MAIN2 must be connected together if the externalcircuit is the one shownin the Figure10.10. It is possible to use different circuits for the zero crossing detection, but the MAIN1 signal rising edge must be synchronized with a main voltage zero crossing and the MAIN2 signal falling edge (1.5) (1) (0.5) 0 0.5 1 1.5 Mains Voltage 10 mS 20 mSec T1 T1 Tmax 8mS Tr Tr/2 Ti Figure 10.9 Phase Angle Partialization mode Figure 10.10 Phase Angle Partialization Zero Crossing must be synchronized with the following main voltage zero crossing, always. The peripheral can be programmed in order to work with 50 or 60 Hz main voltage frequency by setting the REG_CONF10(6) bit, PSF (see Table 10.4). If main voltage frequency is equal to 50 Hz, then Tr, see figure 10.9, is equal to 20 mSec and T1 is: T1 = PERIPH_REG_1(0:7)*(1/25.5)ms. The length of the semiperiod Ti/2 is programmable by using the registers REG_CONF12(0:5) and REG_CONF13, (see figure 10.12).By using a clock master equal to 20 MHz the pulse width is in the range from 0.2 to 250 µs. The duty cycle of Ti is always 50 %. In order to avoid problems for the Triac firing when the load is inductive 8 different pulses are generated by the peripheral. If the time T1 is bigger than a fixed time Tmax then no pulses are generatedand the Triac is maintained off. This feature was implemented in order to avoid the firing of the Triac in the second half period of the main voltage. The firing pulses are generated when the contents of the PERIPH_REG_1 is less or equal to 204, otherwise they are not generated. When the frequency of the main voltage is 50 Hz, T1max is equal to 8 mSec. It is possible to generate a programmable interrupt in four different ways: 1) no Interrupt; 2) Interrupt on the rising edge of the signal MAIN1 3)Interrupt on the falling edge of the signal MAIN2 4) Interrupt on both the edges of the signal MAIN1. The Interrupt is programmableby using the register REG_CONF11(7:6), INTSL 10.4. TRIAC/PWM DRIVER PROGRAMMING 51/99 ST52T301/E301 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |