51 / 156 page ![]() ADE5166/ADE5169/ADE5566/ADE5569 Rev. B | Page 51 of 156 FAULT DETECTION (ADE5166/ADE5169 ONLY) The ADE5166/ADE5169 incorporate a fault detection scheme that warns of fault conditions and allows accurate measurement to continue during a fault event. (This feature is not available in the ADE5566/ADE5569.) The ADE5166/ADE5169 do this by con- tinuously monitoring both current inputs (IPA and IPB). For ease of understanding, these currents are referred to as phase and neutral (return) currents. In the ADE5166/ADE5169, a fault condition is defined when the difference between IPA and IPB is greater than 6.25% of the active channel caused by amplitude or phase. If a fault condition is detected and the inactive channel is larger than the active channel, the ADE5166/ ADE5169 automatically switch current measurement to the inactive channel. During a fault, the active, reactive, and apparent power and the Irms are generated using the larger of the two cur-rents. On power-up, IPA is the current input selected for active, reactive, and apparent power and Irms calculations. To prevent a false alarm, averaging is done for the fault detection, and a fault condition is detected approximately one second after the event. The fault detection is automatically disabled when the voltage signal is less than 0.3% of the full-scale input range. This eliminates false detection of a fault due to noise at light loads. Because the ADE5166/ADE5169 look for a difference between the voltage signals on IPA and IPB, it is important that both current transducers be closely matched. Channel Selection Indication The current channel selected for measurement is indicated by the ICHANNEL bit (Bit 7) in the ACCMODE register (Address 0x0F). When Bit 7 is cleared, IPA is selected; when Bit 7 is set, IPB is selected. The ADE5166/ADE5169 automatically switch from one channel to the other and report the channel configuration in the ACCMODE register. The current channel selected for measurement can also be forced. Setting the SEL_I_CH bits (Bits[5:4]) in the CALMODE register (Address 0x3D) to 01 or 10 selects IPA and IPB, respectively. When both bits are cleared or set, the current channel used for measure- ment is selected automatically, based on the fault detection. Fault Indication The ADE5166/ADE5169 provide an indication of the part going into or out of a fault condition. The new fault condition is indicated by the FAULTSIGN flag (Bit 5) in the Interrupt Status 1 SFR (MIRQSTL, Address 0xDC). When the FAULTSIGN bit (Bit 6) in the ACCMODE register (Address 0x0F) is cleared, the FAULTSIGN flag in the Interrupt Status 1 SFR (MIRQSTL, Address 0xDC) is set when the part is entering a fault condition or a normal condition. When the FAULTSIGN bit (Bit 5) is set in the Interrupt Enable 1 SFR (MIRQENL, Address 0xD9) and the FAULTSIGN flag (Bit 5) in the Interrupt Status 1 SFR (MIRQSTL, Address 0xDC) is set, the 8052 core has a pending ADE interrupt. Fault with Active Input Greater Than Inactive Input If IPA is the active current input (that is, IPA is being used for billing), and the voltage signal on IPB (inactive input) falls below 93.75% of IPA, and the FAULTSIGN bit (Bit 6) of the ACCMODE register (Address 0x0F) is cleared, the FAULTSIGN flag (Bit 5) in the Interrupt Status 1 SFR (MIRQSTL, Address 0xDC) is set. Both analog inputs are filtered and averaged to prevent false triggering of this logic output. As a consequence of the filtering, there is a time delay of approximately 3 sec on the logic output after the fault event. The FAULTSIGN flag is independent of any activity. Because IPA is the active input and it is still greater than IPB, billing is maintained on IPA; that is, no swap to the IPB input occurs. IPA remains the active input. Fault with Inactive Input Greater Than Active Input If the difference between IPB (the inactive input) and IPA (the active input that is being used for billing) becomes greater than 6.25% of IPB, and the FAULTSIGN bit (Bit 6) in the ACCMODE register (Address 0x0F) is cleared, the FAULTSIGN flag (Bit 5) in the Inter- rupt Status 1 SFR (MIRQSTL, Address 0xDC) is set. The IPB analog input becomes the active input. Again, a time constant of about 3 sec is associated with this swap. IPA does not swap back to the active channel until IPA is greater than IPB and the difference between IPA and IPB, in this order, becomes greater than 6.25% of IPB. However, if the FAULTSIGN bit (Bit 6) in the ACCMODE register (Address 0x0F) is set, the FAULTSIGN flag (Bit 5) in the Interrupt Status 1 SFR (MIRQSTL, Address 0xDC) is set as soon as IPA is within 6.25% of IPB. This threshold eliminates concerns about potential chatter between IPA and IPB calibration. Calibration Concerns Typically, when a meter is calibrated, the voltage and current cir- cuits are separated (see Figure 49). Current passes through only the phase circuit or the neutral circuit. Figure 49 shows current being passed through the phase circuit. This is the preferred option because the ADE5166/ADE5169 start billing on the IPA input on power-up. The phase circuit, CT, is connected to IPA in the diagram. Because the current sensors are not perfectly matched, it is impor- tant to match current inputs. The ADE5166/ADE5169 provide a gain calibration register for IPB, IBGAIN (Address 0x1C). IBGAIN is a 12-bit, signed, twos complement register that provides a gain resolution of 0.0244%/LSB. AGND IB IN IPA RF RF CF CF CT CT RB RB 0V VA 0 IPB RF RA VP RF VN CT CF V TEST CURRENT 240V rms + – + – + – Figure 49. Fault Conditions for Inactive Input Greater Than Active Input |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |