| 数据搜索系统,热门电子元器件搜索 |
|
ADM1026JSTZ-R7 数据表(PDF) 12 Page - ON Semiconductor |
|
|
|||||||||||||||||||||||||||||
ADM1026JSTZ-R7 数据表(HTML) 12 Page - ON Semiconductor |
|
12 / 55 page ![]() ADM1026 http://onsemi.com 12 2. Data is sent over the serial bus in sequences of nine clock pulses, 8 bits of data followed by an acknowledge bit from the slave device. Data transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, because a low-to-high transition when the clock is high may be interpreted as a stop signal. If the operation is a write operation, the first data byte after the slave address is a command byte. This tells the slave device what to expect next. It may be an instruction telling the slave device to expect a block write, or it may simply be a register address that tells the slave where subsequent data is to be written. Because data can flow in only one direction as defined by the R/W bit, it is not possible to send a command to a slave device during a read operation. Before doing a read operation, it may first be necessary to do a write operation to tell the slave what type of read operation to expect and/or the address from which data is to be read. 3. When all data bytes have been read or written, stop conditions are established. In write mode, the master pulls the data line high during the 10th clock pulse to assert a stop condition. In read mode, the master device releases the SDA line during the low period before the ninth clock pulse, but the slave device does not pull it low (called No Acknowledge). The master takes the data line low during the low period before the 10th clock pulse, then high during the 10th clock pulse to assert a stop condition. *If it is required to perform several read or write operations in succession, the master can send a repeat start condition instead of a stop condition to begin a new operation. Figure 16. General SMBus Write Timing Diagram R/W 0 SCL SDA 10 1 1 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 ACK. BY SLAVE START BY MASTER FRAME 1 SLAVE ADDRESS FRAME 2 COMMAND CODE 19 1 ACK. BY SLAVE 9 D7 D 6 D5 D4 D3 D2 D1 D0 ACK. BY SLAVE STOP BY MASTER FRAME N DATA BYTE 1 9 9 SCL (CONTINUED) SDA (CONTINUED) D7 D6 D5 D4 D3 D2 D1 D0 ACK. BY SLAVE FRAME 3 DATA BYTE 1 Figure 17. General SMBus Read Timing Diagram R/W 0 SCL SDA 10 1 1 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0 ACK. BY MASTER START BY MASTER FRAME 1 SLAVE ADDRESS FRAME 2 DATA BYTE 19 1 ACK. BY SLAVE 9 D7 D 6 D5 D4 D3 D2 D1 D0 NO ACK. STOP BY MASTER FRAME N DATA BYTE 1 9 9 SCL (CONTINUED) SDA (CONTINUED) D7 D6 D5 D4 D3 D2 D1 D0 ACK. BY MASTER FRAME 3 DATA BYTE 1 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |