| 数据搜索系统,热门电子元器件搜索 |
|
Z8018233FSC 数据表(PDF) 64 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
Z8018233FSC 数据表(HTML) 64 Page - Zilog, Inc. |
|
64 / 109 page ![]() 3-64 Z80182/Z8L182 ZILOG INTELLIGENT PERIPHERAL PRELIMINARY Zilog DS971820600 Figure 61. IUS/IP Register (Z180 MPU, Address xxFEH) Bit 7 Interrupt Under Service (Read/Write) This bit represents a logical OR of each individual IUS bit for the internal MIMIC interrupt daisy chain. An IUS bit is set when an interrupt is registered (IP set) and enabled (IE set), the incoming IEI daisy chain is active (chain enabled) and an interrupt acknowledge cycle is entered. By writing a 1 to this bit the highest priority IUS bit that is set will be reset. Writing a 0 to this bit has no effect. This should be done at the end of every MIMIC Interrupt Service routine. Bit 6 Transmit Holding Register Written (Read Only) This bit is set when the PC/XT/AT writes to the Transmit Holding Register. It is reset when the Z180 MPU reads the Transmit Holding Register. In FIFO mode, this bit is set when the trigger level is reached (4,8,14 bytes available). Note: The THR bit is set (interrupts) when the transmitter FIFO reaches the data available trigger level set in the MPU FCR control register. The bit and interrupt source is cleared when the number of data bytes falls below the set trigger level. 0 0 00000 0 D7 D6 D5 D4 D3 D2 D1 D0 Interrupt Under Service (RD) Reset Highest IUS (WR) Interrupt Pending 6 THR Write 5 TTO Transmitter Timeout 4 RBR Read 3 MCR Write 2 LCR Write 1 DLL Write 1 DLM Write 0 FCR Write or Tx Overrun IUS/IP Register The IUS/IP Register is used by the Z180™ MPU to determine the source of the interrupt. This register will have the appropriate bit set when an interrupt occurs. Bit 5 Transmitter Timeout with Data in FIFO (Read Only) This bit is set when the transmitter FIFO has been idle (no read or write and timer decrements to zero) with data bytes below the trigger level. It is cleared when the FIFO is read or written. Bit 4 Receive Buffer Read (Read Only) This bit is set when the PC/XT/AT reads the Receive Buffer Register. It is reset when the Z180 MPU writes to the Receive Buffer Register. In FIFO mode, this bit is set upon the PC reading all the data in the receive FIFO. Note: RBR is set and interrupts when the receive FIFO has been emptied by the PC. This bit and interrupt are cleared when one or more bytes are written into the receive FIFO by the MPU. Bit 3 Modem Control Register Write (Read Only) This bit is set when the PC/XT/AT writes to the Modem Control Register. It is reset when the Z180™ MPU reads the Modem Control Register. Bit 2 Line Control Register Write (Read Only) This bit is set when the PC/XT/AT writes to the Line Control Register. It is reset when the Z180 MPU reads the Line Control Register. Bit 1 Divisor Latch LS/MS Write (Read Only) This bit is set when the PC/XT/AT writes to the Divisor Latch Least Significant or Most Significant bytes. It is reset when the PC reads the LS/MS register(s). To determine which byte(s) have been written, the Z180 must read either LS or MS locations and then repoll this bit. If only one location is interrupting, the interrupt is cleared when that location is read by the Z180. Bit 0 FIFO Control Register Write (Read Only) This bit is set when the PC/XT/AT writes to the FCR. This bit is also set when Transmit occurs. It is reset when the Z180 MPU reads this register. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |