43 / 80 page ![]() Data Sheet ADAS1000-3/ADAS1000-4 Detection Algorithm Overview The pace pulse amplitude and width varies over a wide range, while its shape is affected by both the internal filtering arising from the decimation process and the low pass nature of the electrodes, cabling, and components used for defibrillation and ESIS protection. The ADAS1000-4 provides user programmable variables to optimize the performance of the algorithm within the ECG system, given all these limiting elements. The default parameter values are probably not optimal for any particular system design; experimentation and evaluation are needed to ensure robust performance. Figure 70. Typical Pace Signal The first step in pace detection is to search the data stream for a valid leading edge. Once a candidate edge is detected, the algorithm verifies that the signal looks like a pulse and then begins searching for a second, opposite polarity edge that meets the pulse width and amplitude criteria and passes the optional noise filters. Only the pulses meeting all requirements are flagged as valid pace pulses. Detection of a valid pace pulse sets the flag or flags in the frame header register and stores amplitude and width information in the PACEDATA register (Address 0x1A; see Table 34). The pace algorithm detects pulses of both negative and positive polarity using a single set of parameters by tracking the slope of the leading edge and making the necessary adjustments to internal parameter signs. This frees the user to concentrate on determining appropriate threshold values based on pulse shape without concern for pulse polarity. Figure 71. Overview of Pace Algorithm The three user controlled parameters for the pace detection algorithm are Pace Amplitude Threshold (PACEAMPTH), Pace Level Threshold (PACELVLTH), and Pace Edge Threshold (PACEEDGETH). PACEAMPTH PACE WIDTH LEADING EDGE LEADING EDGE STOP PACELVLTH PACEEDGETH RECHARGE PULSE PACE PULSE NO ENABLE PACE DETECTION SELECT LEADS FLAG PACE DETECTED TRAILING EDGE DETECTED? START START PULSE WIDTH TIMER START NOISE FILTERS (if enabled) NOISE FILTER PASSED? PULSE WIDTH > 100µs AND <2ms UPDATE REGISTERS WITH WIDTH AND HEIGHT NO NO YES YES YES START PACE DETECTION ALGORITHM NO FIND LEADING EDGE A > PACEEDGETH? YES NO FIND END OF LEADING EDGE B < PACELVL YES PACE AMPLITUDE > PACEAMPTH NO YES YES Rev. B | Page 43 of 80 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |