ADAS1000-4BSTZ 数据表(PDF) 60 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADAS1000-4BSTZ 数据表(HTML) 60 Page - Analog Devices |
|
60 / 80 page ![]() ADAS1000-3/ADAS1000-4 Data Sheet Table 30. Respiration Control Register (RESPCTL) Address 0x03, Reset Value = 0x0000001 AA REE AA /W Default Bit Name Function [23:17] Reserved Reserved, set to 0. R/W 0 16 RESPALTFREQ Setting this bit to 1 makes the respiration waveform on the GPIO3 pin periodic every cycle. Use in conjunction with RESFREQ to select drive frequency. 0 (default) = periodic every N cycles (default). 1 = periodic every cycle. R/W 0 15 RESPEXTSYNC Set this bit to 1 to drive the MSB of the respiration DAC out onto the GPIO3 pin. This signal can be used to synchronize an external generator to the respiration carrier. It is a constant period only when RESPALTFREQ = 1. 0 (default) = normal GPIO3 function. 1 = MSB of RESPDAC driven onto the GPIO3 pin. R/W 0 14 RESPEXTAMP For use with an external instrumentation amplifier with respiration circuit. Bypasses the on-chip amplifier stage and input directly to the ADC. See Figure 69. 0 (default) = disabled. 1 = enabled. R/W 0 13 RESPOUT Selects external respiration drive output. RESPDAC_RA is automatically selected when RESPCAP = 1 0 (default) = RESPDAC_LL and RESPDAC_RA. 1 = RESPDAC_LA and RESPDAC_RA. R/W 0 12 RESPCAP Selects source of respiration capacitors. 0 (default) = use internal capacitors. 1 = use external capacitors. R/W 0000 [11:8] RESPGAIN [3:0] Respiration in amp gain (saturates at 10). 0000 (default) = ×1 gain. 0001 = ×2 gain. 0010 = ×3 gain. … 1000 = ×9 gain. 1001 = ×10 gain. 11xx = ×10 gain. R/W 0 7 RESPEXTSEL Selects between EXT_RESP _LA or EXT_RESP_LL paths. Applies only if the external respiration is selected in RESPSEL. EXT_RESP_RA is automatically enabled. 0 (default) = EXT_RESP_LL. 1 = EXT_RESP_LA. R/W 00 [6:5] RESPSEL [1:0] Set leads for respiration measurement. 00 (default) = Lead I. 01 = Lead II. 10 = Lead III. 11 = external respiration path. R/W 00 [4:3] RESPAMP Set the test tone amplitude for respiration drive signal. 00 (default) = amplitude/8. 01 = amplitude/4. 10 = amplitude/2. 11 = amplitude. R/W 00 [2:1] RESPFREQ Set frequency for respiration. RESPFREQ RESPALTFREQ = 0 RESPALTFREQ = 1 (periodic) 00 (default) 56 kHz 64 kHz 01 54 kHz 56.9 kHz 10 52 kHz 51.2 kHz 11 50 kHz 46.5 kHz R/W 0 0 RESPEN Enable respiration. 0 (default) = respiration disabled. 1 = respiration enabled. 1 ADAS1000-4 model only, ADAS1000-3 model does not contain this feature. Rev. B | Page 60 of 80 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |