| 数据搜索系统,热门电子元器件搜索 |
|
TMP86FS49AIUG 数据表(PDF) 36 Page - Toshiba Semiconductor |
|
|
|||||||||||||||||||||||||||||
TMP86FS49AIUG 数据表(HTML) 36 Page - Toshiba Semiconductor |
|
36 / 296 page ![]() Page 20 2. Operational Description 2.2 System Clock Controller TMP86FS49AIUG Figure 2-8 Edge-sensitive Release Mode STOP mode is released by the following sequence. 1. In the dual-clock mode, when returning to NORMAL2, both the high-frequency and low- frequency clock oscillators are turned on; when returning to SLOW1 mode, only the low- frequency clock oscillator is turned on. In the single-clock mode, only the high-frequency clock oscillator is turned on. 2. A warm-up period is inserted to allow oscillation time to stabilize. During warm up, all internal operations remain halted. Four different warm-up times can be selected with the SYSCR1<WUT> in accordance with the resonator characteristics. 3. When the warm-up time has elapsed, normal operation resumes with the instruction follow- ing the STOP mode start instruction. Note 1: When the STOP mode is released, the start is made after the prescaler and the divider of the timing generator are cleared to "0". Note 2: STOP mode can also be released by inputting low level on the RESET pin, which immediately performs the normal reset operation. Note 3: When STOP mode is released with a low hold voltage, the following cautions must be observed. The power supply voltage must be at the operating voltage level before releasing STOP mode. The RESET pin input must also be “H” level, rising together with the power supply voltage. In this case, if an external time constant circuit has been connected, the RESET pin input voltage will increase at a slower pace than the power supply voltage. At this time, there is a danger that a reset may occur if input voltage level of the RESET pin drops below the non-inverting high-level input voltage (Hysteresis input). Note 1: The warm-up time is obtained by dividing the basic clock by the divider. Therefore, the warm-up time may include a certain amount of error if there is any fluctuation of the oscillation frequency when STOP mode is released. Thus, the warm-up time must be considered as an approximate value. Table 2-2 Warm-up Time Example (at fc = 16.0 MHz, fs = 32.768 kHz) WUT Warm-up Time [ms] Return to NORMAL Mode Return to SLOW Mode 00 01 10 11 12.288 4.096 3.072 1.024 750 250 5.85 1.95 NORMAL operation NORMAL operation VIH STOP mode is released by the hardware at the rising edge of STOP pin input. Warm up STOP mode started by the program. STOP operation STOP operation STOP pin XOUT pin |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |