28 / 96 page ![]() ADP1046 Data Sheet Rev. 0 | Page 28 of 96 POWER READINGS The output power value register (Register 0x19) is the product of the VS3 voltage value and the CS2 current value. Therefore, a combination of the formulas in the Voltage Readings section and the CS2+, CS2− Pins section is used to calculate the power reading in watts. This register is a 16-bit word. It multiplies two 12-bit numbers and discards the eight LSBs. POUT = VOUT × IOUT For example, POUT = 12 V × 4.453 A = 53.436 W POWER MONITORING ACCURACY The ADP1046 power monitoring accuracy is specified relative to the full-scale range of the signal that it is measuring. FIRST FLAG FAULT ID AND VALUE REGISTERS When the ADP1046 registers several fault conditions, it stores the value of the first fault in a dedicated register. For example, if the overtemperature (OTP) fault is registered followed by an OVP fault, the OTP flag is stored in the first flag ID register (Register 0x10). This register gives the user more information for fault diagnosis than a simple flag. The contents of this register are latched, meaning that they are stored until read by the user. The contents are also reset by toggling PSON. If a flag is set to be ignored, it does not appear in the first flag register. EXTERNAL FLAG INPUT (FLAGIN PIN) The FLAGIN pin can be used to send an external fault signal into the ADP1046. Register 0x0A[3:0] can be used to program the FLAGIN flag to trigger an action. TEMPERATURE READINGS (RTD PIN) The RTD pin is set up for use with an external negative tempera- ture coefficient (NTC) thermistor. The RTD pin has an internal programmable current source. An ADC monitors the voltage on the RTD pin. The RTD temperature value register, Register 0x1A, is updated every 10 ms. The ADP1046 stores every ADC sample for 10 ms and then outputs the average value at the end of the 10 ms period. The RTD ADC has an input range of 1.6 V and a resolution of 12 bits, which means that the LSB size is 1.6 V/4096 = 390.625 μV. The user is limited to an input range of 1.3 V, which means that the maximum ADC output code is limited to 1.3 V/390.6 μV = 3328. The output of the RTD ADC is linearly proportional to the vol- tage on the RTD pin. However, thermistors exhibit a nonlinear function of resistance vs. temperature. Therefore, the user must perform postprocessing on the RTD ADC reading to accurately read the temperature. By connecting an external resistor (REXT) in parallel with the NTC thermistor (TH), a constant current can be used to achieve linearization (see Figure 36). ADC DAC RTD TH REXT Figure 36. Temperature Measurement Using Thermistor An internal, precision current source of 10 μA, 20 μA, 30 μA, or 40 μA can be selected in Register 0x11. This current source can be trimmed by means of an internal DAC to compensate for thermistor accuracy (see the RTD/OTP Trim section). The user can select the output current source using Bits[7:6] of Register 0x11. The ADP1046 implements a linearization scheme based on a preselected combination of external components and current selection for best performance when measuring linearized temperatures in degrees Celsius in the industrial range. For more information about the required thermistor and selecting and trimming the precision current sources, see the Temperature Linearization Scheme section. Optionally, the user can process the RTD reading and perform postprocessing in the form of a lookup table or polynomial equation to match the specific NTC thermistor used. With the internal current source set to 46 μA, the equation to calculate the ADC code at a specified NTC thermistor value (Rx) is given by the following formula: ADC CODE = 46 μA × Rx/1.6 × 4096 For example, at 60°C, the NTC thermistor at the RTD pin is 21.82 kΩ. RTD_ADC_CODE = 46 μA × 21.82 kΩ/1.6 × 4096 = 2570 FLAGS OTP FLAG OTP THRESHOLD REG 0x2F[7:0] RTD TEMPERATURE VALUE REGISTER REG 0x1A[15:4] RTD TEMPERATURE VALUE IN °C REG 0x1B[7:0] SIGNAL CONDITIONING 10µA/20µA/30µA/40µA RTD 100kΩ NTC 16.5kΩ RTD ADC Figure 37. RTD Pin Internal Details |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |