31 / 58 page ![]() SMSC DS – PPC34C60 Page 31 Rev. 06/01/2001 ADVANCED INFORMATION 6 SYSTEM DATA BUS CYCLES The System Data Bus is controlled by an internal state machine with seven states as shown below in FIGURE 7. The state machine is clocked by the BUSCLK which is software- programmable as SCLK divided by 2, 3, 5, or 6. Three types of operations are performed by the bus interface: a Bus Cycle, a DRAM Access, and a DRAM Refresh. Refer to Tables 4-6 for the state flow description for each operation. The bus controller normally sits in the idle state. When a bus interface operation is kicked off, it advances to state 1. It then advances to the next state at every BUSCLK cycle. After state 7, the controller returns to idle. FIGURE 7 - GENERIC SYSTEM DATA BUS CYCLE BUS CYCLE TIMING When an Address Write cycle selects a bus write, the next data received is written to the bus. The interface must, however, know whether to expect an 8 or 16 bit bus address. To determine the bus width, a bus cycle is started from the Address Write cycle. This "pre-write" cycle asserts chip select and samples and latches nIO16. The write cycle is initiated after the first byte received for 8 bit writes, or after the second byte of data for 16 bit writes. Table 4 - Bus Cycle State Flow Description IDLE Write: Data bus drivers are disabled, nRAS and nCAS are inactive. STATE 1 Read: If necessary, data advances to next element in the FIFO buffer. nCAS goes active for first refresh. STATE 2 Write: Data is latched into bus latches. nRAS goes active for first refresh. STATE 3 Chip Select goes active. STATE 4 nIO16 is sampled. Read: nRD goes active. Write: If nIO16 is sampled low and this is the first byte received, then nWR remains inactive. If nIO16 is sampled high or if nIO16 is sampled low and this is the second byte received, then nWR goes active and data bus drivers are enabled. nRAS and nCAS go inactive. STATE 5 Wait for data bus to stabilize, nCAS goes active for second refresh. STATE 6 Read: Data is latched, nRD goes inactive. Write: nWR goes inactive. nRAS goes active for second refresh. STATE 7 Chip select goes inactive. Read: Data advances to next element if possible. Write: Data bus drivers are disabled. Table 5 - DRAM Access State Flow Description IDLE nRAS and nCAS go inactive. STATE 1 Row Address output. STATE 2 nRAS goes active. Read: nRD goes active. Write: nWR goes active. STATE 3 Column Address output Write: Data bus drivers enabled. STATE 4 nCAS goes active. STATE 5 Column Address incremented. Read: Data is latched. Write: Data bus drivers disabled. (If multiple accesses are needed, States 3-5 are repeated) STATE 6 nRAS, nCAS, nRD, nWR go inactive. STATE 7 nRAS precharge time. Idle State 1 State 2 State 3 State 4 State 5 State 6 State 7 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |