56 / 104 page ![]() ADE7880 Data Sheet Rev. A | Page 56 of 104 V I ACTIVE (–) REACTIVE (–) PF (+) CAPACITIVE: CURRENT LEADS VOLTAGE INDUCTIVE: CURRENT LAGS VOLTAGE ACTIVE (+) REACTIVE (–) PF (–) ACTIVE (–) REACTIVE (+) PF (–) ACTIVE (+) REACTIVE (+) PF (+) θ = +60° PF = –0.5 θ = –60° PF = +0.5 Figure 81. Capacitive and Inductive Loads As shown in Figure 81, the reactive power measurement is negative when the load is capacitive, and positive when the load is inductive. The sign of the reactive power can therefore be used to reflect the sign of the power factor. Note that the ADE7880 computes the fundamental reactive power, so its sign is used as the sign of the absolute power factor. If the fundamental reactive power is in no load state, then the sign of the power factor is the sign of the total active power. The mathematical definition of power factor is shown in Equation 47: Power Factor = (Sign Fundamental Reactive Power) × Power Apparent Power Active Total (47) As previously mentioned, the ADE7880 provides a power factor measurement on all phases simultaneously. These readings are provided into three 16-bit signed registers, APF (Address 0xE609 ) for Phase A, BPF (Address 0xE60A) for Phase B, and CPF (Address 0xE60B) for Phase C. The registers are signed twos complement register with the MSB indicating the polarity of the power factor. Each LSB of the APF, BPF, and CPF registers equates to a weight of 2−15, hence the maximum register value of 0x7FFF equating to a power factor value of 1. The minimum register value of 0x8000 corresponds to a power factor of −1. If because of offset and gain calibrations, the power factor is outside the −1 to +1 range, the result is set at −1 or +1 depending on the sign of the fundamental reactive power. By default the instantaneous total phase active and apparent powers are used to calculate the power factor and the registers are updated at a rate of 8 kHz. The sign bit is taken from the instantaneous fundamental phase reactive energy measurement on each phase. Should a measurement with more averaging be required, the ADE7880 provides an option of using the line cycle accumulation measurement on the active and apparent energies to determine the power factor. This option provides a more stable power factor reading. This mode is enabled by setting the PFMODE bit (Bit 7) in the LCYCMODE register (Address 0xE702). When this mode is enabled the line cycle accumulation mode must be enabled on both the active and apparent energies. This is done by setting the xLWATT and xLVA bits in the LCYCMODE register (Address 0xE702). The update rate of the power factor measurement is now an integral number of half line cycles that can be programmed into the LINECYC register (Address 0xE60C). For full details on setting up the line cycle accumulation mode see the Line Cycle Active Energy Accumulation Mode and Line Cycle Apparent Energy Accumulation Mode sections. Note that the power factor measurement is effected by the no load condition if it is enabled (see the No Load Condition section). If the apparent energy no load is true, then the power factor measurement is set to 1. If the no load condition based on total active and apparent energies is true, the power factor measurement is set at 0. The ADE7880 also computes the power factor on the fundamental and harmonic components based on the fundamental and harmonic active, reactive and apparent powers. See the Harmonics Calculations section for details. HARMONICS CALCULATIONS The ADE7880 contains a harmonic engine that analyzes one phase at a time. Harmonic information is computed with a no attenuation pass band of 2.8 kHz (corresponding to a −3 dB bandwidth of 3.3 kHz) and it is specified for line frequencies between 45 Hz and 66 Hz. Neutral current can also be analyzed simultaneously with the sum of the phase currents. Figure 82 presents a synthesized diagram of the harmonic engine, its settings and its output registers. Theory of Operation Consider an nonsinusoidal ac system supplied by a voltage, v(t) that consumes the current i(t). Then sin 2 ) ( 1 ∑ ∞ = = k k V t v (kωt + φk) (48) () k k k t k I t i γ ω + = ∑ ∞ = sin 2 ) ( 1 where: Vk, Ik are rms voltage and current, respectively, of each harmonic. Φk, γk are the phase delays of each harmonic. ω is the angular velocity at the fundamental (line) frequency f. The ADE7880 harmonics calculations are specified for line frequencies between 45 Hz and 66 Hz. The phase nominal voltage used as time base must have an amplitude greater than 20% of full scale. The number of harmonics N that can be analyzed within the 2.8 kHz pass band is the whole number of 2800/f. The absolute maximum number of harmonics accepted by the ADE7880 is 63. ⎥ ⎦ ⎤ ⎢ ⎣ ⎡ = f N 2800 , N≤63 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |