82 / 120 page ![]() ADE7978/ADE7933/ADE7932 Data Sheet Rev. 0 | Page 82 of 120 APPLICATIONS INFORMATION The ADE7978 and ADE7933/ADE7932 chipset was designed for use in 3-phase energy metering systems in which one master device, usually a microcontroller, manages the ADE7978 through an I2C or SPI interface. The ADE7978 then manages two, three, or four ADE7933/ADE7932 devices. The ADE7978 is not the only chip capable of managing multiple ADE7933/ADE7932 devices. Any microcontroller that conforms to the ADE7933/ADE7932 serial interface can manage the devices correctly. (For more information, see the Bit Stream Communication Between the ADE7978 and the ADE7933/ADE7932 section). However, similar devices, such as the ADE7913/ADE7912 3-channel, isolated, Σ-Δ ADCs with an SPI interface, may be more suitable for direct interfacing with a microcontroller. For more information about the ADE7913/ ADE7912 ADCs, see the product pages for these devices. Figure 101 shows Phase A of a 3-phase energy meter. The Phase A current, IA, is sensed with a shunt. A pole of the shunt is connected to the IM pin of the ADE7933/ADE7932 and becomes the ground of the isolated side of the ADE7933/ADE7932, GNDISO. The Phase A to neutral voltage, VAN, is sensed with a resistor divider, and the VM pin is also connected to the IM and GNDISO pins. Note that the voltages measured by the ADCs of the ADE7933/ ADE7932 are opposite to VAN and IA, a classic approach in single- phase metering. The other ADE7933/ADE7932 devices, which monitor Phase B and Phase C, are connected in a similar way. NEUTRAL PHASE A PHASE A ADE7932/ ADE7933 IP IM GNDISO V1P VM IA VAN Figure 101. Phase A ADE7933/ADE7932 Current and Voltage Sensing Figure 102 shows how to connect the ADE7933/ADE7932 inputs when the neutral line of a 3-phase system is monitored. The neutral current is sensed using a shunt, and the voltage across the shunt is measured at the fully differential inputs IP and IM. The neutral to earth voltage is sensed with a voltage divider at the single-ended inputs V1P and VM. NEUTRAL EARTH NEUTRAL LINE ADE7932/ ADE7933 IP IM V1P VM GNDISO IN VN Figure 102. Neutral Line and Neutral to Earth Voltage Monitoring with the ADE7933/ADE7932 ADE7978 AND ADE7933/ADE7932 IN POLYPHASE ENERGY METERS A polyphase energy meter must manage three phases and an optional neutral line. Figure 103 shows an example of a 3-phase meter built for a 4-wire wye configuration. Three ADE7933/ ADE7932 devices read the phase currents and voltages. The fourth ADE7933/ADE7932 manages the neutral line measure- ments. If the neutral line measurements are not required, only three ADE7933/ADE7932 devices are used (see Figure 104); in this configuration, the DATA_N pin of the ADE7978 is connected to VDD. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |