45 / 76 page ![]() AD9549 Rev. D | Page 45 of 76 Read If the instruction word is for a read operation (I15 = 1), the next N × 8 SCLK cycles clock out the data from the address specified in the instruction word, where N is 1, 2, 3, 4, as determined by [W1:W0]. In this case, 4 is used for streaming mode where four or more words are transferred per read. The data readback is valid on the falling edge of SCLK. The default mode of the AD9549 serial control port is bidirec- tional mode, and the data readback appears on the SDIO pin. It is possible to set the AD9549 to unidirectional mode by writing to the SDO active bit at Register 0x0000[7] = 0; in that mode, the requested data appears on the SDO pin. By default, a read request reads the register value that is currently in use by the AD9549. However, setting Register 0x0004[0] = 1 causes the buffered registers to be read instead. The buffered registers are the ones that take effect during the next I/O update. AD9549 CORE UPDATE REGISTERS TOGGLE IO_UPDATE PIN SCLK SDIO SDO CSB SERIAL CONTROL PORT Figure 52. Relationship Between Serial Control Port Register Buffers and Control Registers of the AD9549 The AD9549 uses Register 0x0000 to Register 0x0509. Although the AD9549 serial control port allows both 8-bit and 16-bit instructions, the 8-bit instruction mode provides access to only five address bits ([A4:A0]), which restricts its use to Address Space 0x0000 to Address Space 0x0031. The AD9549 defaults to 16-bit instruction mode on power-up, and 8-bit instruction mode is not supported. THE INSTRUCTION WORD (16 BITS) The MSB of the instruction word is R/W, which indicates whether the instruction is a read or a write. The next two bits, [W1:W0], are the transfer length in bytes. The final 13 bits are the address ([A12:A0]) at which to begin the read or write operation. For a write, the instruction word is followed by the number of bytes of data indicated by Bits[W1:W0], which is interpreted according to Table 10. Bits[A12:A0] select the address within the register map that is written to or read from during the data transfer portion of the communications cycle. The AD9549 uses all of the 13-bit address space. For multibyte transfers, this address is the starting byte address. Table 10. Byte Transfer Count W1 W0 Bytes to Transfer (Excluding the 2-Byte Instruction) 0 0 1 0 1 2 1 0 3 1 1 Streaming mode MSB/LSB FIRST TRANSFERS The AD9549 instruction word and byte data may be MSB first or LSB first. The default for the AD9549 is MSB first. The LSB first mode can be set by writing a 1 to Register 0x0000[6] and requires that an I/O update be executed. Immediately after the LSB first bit is set, all serial control port operations are changed to LSB first order. When MSB first mode is active, the instruction and data bytes must be written from MSB to LSB. Multibyte data transfers in MSB first format start with an instruction byte that includes the register address of the most significant data byte. Subsequent data bytes must follow in order from high address to low address. In MSB first mode, the serial control port internal address generator decrements for each data byte of the multibyte transfer cycle. When LSB first = 1 (LSB first), the instruction and data bytes must be written from LSB to MSB. Multibyte data transfers in LSB first format start with an instruction byte that includes the register address of the least significant data byte followed by multiple data bytes. The serial control port internal byte address generator increments for each byte of the multibyte transfer cycle. The AD9549 serial control port register address decrements from the register address just written toward 0x0000 for multi- byte I/O operations if the MSB first mode is active (default). If the LSB first mode is active, the serial control port register address increments from the address just written toward 0x1FFF for multibyte I/O operations. Unused addresses are not skipped during multibyte I/O operations. The user should write the default value to a reserved register and should write only 0s to unmapped registers. Note that it is more efficient to issue a new write command than to write the default value to more than two consecutive reserved (or unmapped) registers. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |