| 数据搜索系统,热门电子元器件搜索 |
|
TMP86FS49AIUG 数据表(PDF) 262 Page - Toshiba Semiconductor |
|
|
|||||||||||||||||||||||||||||
TMP86FS49AIUG 数据表(HTML) 262 Page - Toshiba Semiconductor |
|
262 / 296 page ![]() Page 246 20. Serial PROM Mode 20.6 Operation Mode TMP86FS49AIUG 20.6.3 RAM Loader Mode (Operation Command: 60H) Table 20-9 shows RAM loader mode process. Note 1: “xxH × 3” indicates that the device enters the halt condition after sending 3 bytes of xxH. For details, refer to " 20.7 Error Code ". Note 2: Refer to " 20.9 Intel Hex Format (Binary) ". Note 3: Refer to " 20.8 Checksum (SUM) ". Note 4: Refer to " 20.10 Passwords ". Note 5: If addresses from FFE0H to FFFFH are filled with “FFH”, the passwords are not compared because the device is consid- ered as a blank product. Transmitting a password string is not required. Even in the case of a blank product , it is required to specify the password count storage address and the password comparison start address. Transmit these data from the external controller. If a password error occurs due to incorrect password count storage address or password comparison start address, TMP86FS49AIUG stops UART communication and enters the halt condition. Therefore, when a password error occurs, initialize TMP86FS49AIUG by the RESET pin and reactivate the serial ROM mode. Note 6: After transmitting a password string, the external controller must not transmit only an end record. If receiving an end record after a password string, the device may not operate correctly. Note 7: If the read protection is enabled or a password error occurs, TMP86FS49AIUG stops UART communication and enters the halt condition. In this case, initialize TMP86FS49AIUG by the RESET pin and reactivate the serial PROM mode. Table 20-9 RAM Loader Mode Process Transfer Bytes Transfer Data from External Control- ler to TMP86FS49AIUG Baud Rate Transfer Data from TMP86FS49AIUG to External Controller BOOT ROM 1st byte 2nd byte Matching data (5AH) - 9600 bps 9600 bps - (Automatic baud rate adjustment) OK: Echo back data (5AH) Error: Nothing transmitted 3rd byte 4th byte Baud rate modification data (See Table 20-4) - 9600 bps 9600 bps - OK: Echo back data Error: A1H × 3, A3H × 3, 62H × 3 (Note 1) 5th byte 6th byte Operation command data (60H) - Modified baud rate Modified baud rate - OK: Echo back data (60H) Error: A1H × 3, A3H × 3, 63H × 3 (Note 1) 7th byte 8th byte Password count storage address bit 15 to 08 (Note 4) Modified baud rate - OK: Nothing transmitted Error: Nothing transmitted 9th byte 10th byte Password count storage address bit 07 to 00 (Note 4) Modified baud rate - OK: Nothing transmitted Error: Nothing transmitted 11th byte 12th byte Password comparison start address bit 15 to 08 (Note 4) Modified baud rate - OK: Nothing transmitted Error: Nothing transmitted 13th byte 14th byte Password comparison start address bit 07 to 00 (Note 4) Modified baud rate - OK: Nothing transmitted Error: Nothing transmitted 15th byte : m’th byte Password string (Note 5) - Modified baud rate - OK: Nothing transmitted Error: Nothing transmitted m’th + 1 byte : n’th - 2 byte Intel Hex format (Binary) (Note 2) Modified baud rate Modified baud rate - - n’th - 1 byte - Modified baud rate OK: SUM (Upper byte) (Note 3) Error: Nothing transmitted n’th byte - Modified baud rate OK: SUM (Lower byte) (Note 3) Error: Nothing transmitted RAM - The program jumps to the start address of RAM in which the first transferred data is written. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |