Back Button ZUSBOPTSC01ZAC Datasheet HTML 238Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 239Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 240Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 241Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 242Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 243Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 244Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 245Page - Zilog, Inc. ZUSBOPTSC01ZAC Datasheet HTML 246Page - Zilog, Inc. Next Button
Zoom Inzoom in Zoom Outzoom out
 242 / 402 page
background image
Program Memory
P R E L I M I N A R Y
PS024604-1005
Z8 Encore!® Motor Control Flash MCUs
Product Specification
220
Flash Frequency High and Low Byte Registers
The Flash Frequency High and Low Byte registers, shown in Tables 120 and 121, com-
bine to form a 16-bit value, FFREQ, to control timing for Flash program and erase opera-
tions. The 16-bit Flash Frequency registers must be written with the system clock
frequency in kilohertz for Program and Erase operations. Calculate the Flash Frequency
value using the following equation:
Flash programming and erasure is not supported for system clock frequencies below
32KHz, above 20MHz, or outside of the valid operating frequency range for the device.
The Flash Frequency High and Low Byte registers must be loaded with the correct value
to ensure proper program and erase times.
Bit
Position
Value
Description
[7:0]]
SECTn
0
Sector Protect
Sector n can be programmed or erased from user code.
1Sector n is protected and cannot be programmed or erased from user code.
FFREQ[15:0] = {FFREQH[7:0],FFREQL[7:0]} =
System Clock Frequency
1000
Table 120. Flash Frequency High Byte Register (FFREQH)
BITS
7
6
5
4
3
2
1
0
FIELD
FFREQH
RESET
00H
R/W
R/W
ADDR
FFAH
Caution:



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


数据表 下载

Go To PDF Page


链接网址



ALLDATASHEET是否为您带来帮助?  [ DONATE ] 

关于 Alldatasheet   |   广告服务   |   联系我们   |   隐私政策   |   数据表链接    |   链接交换   |   制造商名单
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com