| 数据搜索系统,热门电子元器件搜索 |
|
28HS01GTAM03 数据表(PDF) 29 Page - Infineon Technologies AG |
|
|
|||||||||||||||||||||||||||||
28HS01GTAM03 数据表(HTML) 29 Page - Infineon Technologies AG |
|
29 / 138 page ![]() Datasheet 29 of 138 002-18216 Rev. *W 2022-01-18 256Mb/512Mb/1Gb SEMPER™ Flash Octal interface, 1.8V/3.0V Features 4.1.1 ECC error reporting There are five methods for reporting to the host system when ECC errors are detected. • ECC Data Unit Status provides the status of 1-bit or 2-bit errors in data units. • ECC Status Register provides the status of 1-bit or 2-bit errors since the last ECC clear or reset. • The Address Trap Register captures the address location of the first ECC error encountered after POR or reset during memory array read. • An ECC Error Detection counter keeps a tally of the number of 1-bit or 2-bit errors that have occurred in data units during reads. • The Interrupt (INT#)output canbe enabled toindicatewheneither a 1-bitor 2-biterror isdetected asdatais read. 4.1.1.1 ECC data unit status (EDUS) • The status of ECC in each data unit is provided by the 8-bit ECC Data Unit Status. • The ECC status transaction outputs the ECC status of the addressed data unit. The contents of the ECC Data Unit status then indicate, for the selected data unit, whether there is a 1-bit error corrected, 2-bit error detected, or the ECC is disabled for that data unit. Table 9 ECC data unit status Bits Fieldname Function Read/Write N = Nonvolatile V = Volatile Factorydefault (binary) Description EDUS[7:4] RESRVD Reserved For Future Use V => R 0000 These bits are Reserved for future use. EDUS[3] ECC2BD ECC Error 2-bit Error Detection Flag V => R 0 This bit indicates whether a two bit error is detected in the data unit, if two bit ECC error detection is enabled CFR4V[3] = 1. When CFR4V[3] = 0 and 2-bit error detection is disabled, ECC2BD bit will always be ‘0’. Note: If 2 bit error detection is enabled (CFR4V[3] = 1), the ECCOFF bit will not be set to 1b while performing single byte programming or bit walking in a data unit that was already partially programmed. An attempt to do such byte programming or bit walking will result in a Program Error. Selection Options: 1 = Two Bit Error detected 0 = No error EDUS[2] RESRVD Reserved For Future Use V => R 0 This bit is Reserved for future use. EDUS[1] ECC1BC ECC Error 1-bit Error Detection and Correction Flag V => R 0 This bit indicates whether an error was corrected in the data unit. Selection Options: 1 = Single Bit Error corrected in the addressed data unit 0 = No single bit error was corrected in the addressed data unit EDUS[0] ECCOFF Data Unit ECC Off/On Flag V => R 0 This bit indicates whether the ECC syndrome is off in the data unit. Selection Options: 1 = ECC is OFFin the selected data unit 0 = ECC is ON in the selected data unit Dependency: CFR4x[3] |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |