92 / 130 page ![]() LTM4686B 92 Rev. 0 For more information www.analog.com APPENDIX C: PMBUS COMMAND DETAILS This command has two data bytes and is formatted in Linear_16u format. VOUT_UV_WARN_LIMIT The VOUT_UV_ WARN_LIMIT command reads the value of the output voltage measured at the sense pins, in volts, which causes an output voltage low warning. In response to the VOUT_UV_WARN_LIMIT being exceeded, the device: • Sets the NONE_OF_THE_ABOVE bit in the STATUS_BYTE • Sets the VOUT bit in the STATUS_WORD • Sets the VOUT Undervoltage Warning bit in the STATUS_VOUT command • Notifies the host by asserting ALERT pin, unless masked. This condition is detected by the ADC so the response time may be up to 90ms, typical. This command has two data bytes and is formatted in Linear_16u format. VOUT_UV_FAULT_LIMIT The VOUT_UV_FAULT_LIMIT command reads the value of the output voltage measured at the sense pins, in volts, which causes an output undervoltage fault. This command has two data bytes and is formatted in Linear_16u format. MFR_VOUT_MAX The MFR_VOUT_MAX command is the maximum output voltage in volts for each channel including VOUT_OV_FAULT_ LIMIT. If the output voltages are set to high range (Bit 1 of MFR_PWM_MODE set to a 0) MFR_VOUT_MAX for channel 0 and 1 is 5.7V. If the output voltages are set to low range (Bit 1 of MFR_PWM_MODE set to a 1) the MFR_VOUT_MAX for both channels is 2.75V. Entering VOUT_COMMAND values greater than this will result in a CML fault and the output voltage setting will be clamped to the maximum level. This read-only command has 2 data bytes and is formatted in Linear_16u format. CURRENT Input Current Calibration COMMAND NAME CMD CODE DESCRIPTION TYPE PAGED DATA FORMAT UNITS NVM DEFAULT VALUE MFR_IIN_OFFSET 0xE9 Coefficient used to add to the input current to account for the IQ of the part. R/W Word Y L11 A Y 0.04816 0x9315 MFR_IIN_OFFSET The MFR_IIN_OFFSET command allows the user to set an input current representing the quiescent current of each channel. For accurate results at low output current, the part should be in continuous conduction mode. (MFR_PWM_ MODE[0] = 1b). See Table 8 for recommended values. This command has 2 data bytes and is formatted in Linear_5s_11s format. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |