| 数据搜索系统,热门电子元器件搜索 |
|
LTM4686BIVPBF 数据表(PDF) 100 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4686BIVPBF 数据表(HTML) 100 Page - Analog Devices |
|
100 / 130 page ![]() LTM4686B 100 Rev. 0 For more information www.analog.com APPENDIX C: PMBUS COMMAND DETAILS Fault Responses Output Voltage COMMAND NAME CMD CODE DESCRIPTION TYPE PAGED DATA FORMAT UNITS NVM DEFAULT VALUE VOUT_OV_FAULT_RESPONSE 0x41 Action to be taken by the device when an output overvoltage fault is detected. R/W Byte Y Reg Y 0x80 VOUT_UV_FAULT_RESPONSE 0x45 Action to be taken by the device when an output undervoltage fault is detected. R/W Byte Y Reg Y 0xB8 TON_MAX_FAULT_ RESPONSE 0x63 Action to be taken by the device when a TON_MAX_FAULT event is detected. R/W Byte Y Reg Y 0xB8 VOUT_OV_FAULT_RESPONSE The VOUT_OV_FAULT_RESPONSE command instructs the device on what action to take in response to an output overvoltage fault. The data byte is in the format given in Table 24. The device also: • Sets the VOUT_OV bit in the STATUS_BYTE • Sets the VOUT bit in the STATUS_WORD • Sets the VOUT Overvoltage Fault bit in the STATUS_VOUT command • Notifies the host by asserting ALERT pin, unless masked. The only value recognized for this command are: 0x80–The device shuts down (disables the output) and the unit does not attempt to retry. The output remains disabled until the fault is cleared (PMBus, Part II, Section 10.7). 0xB8–The device shuts down (disables the output) and device attempts retry continuously, without limitation, until it is commanded OFF (by the RUN pin or OPERATION command or both), bias power is removed, or another fault condition causes the unit to shut down. 0x4n The device shuts down and the unit does not attempt to retry. The output remains disabled until the part is com- manded OFF then ON or the RUN pin is asserted low then high or MFR_RESET or RESTORE_USER_ALL through the command or removal of SVIN. The OV fault must remain active for a period of n • 10µs, where n is a value from 0 to 7. 0x78+n The device shuts down and the unit attempts to retry continuously until either the fault condition is cleared or the part is commanded OFF then ON or the RUN pin is asserted low then high or MFR_RESET or RESTORE_USER_ALL through the command or removal of SVIN. The OV fault must remain active for a period of n • 10µs, where n is a value from 0 to 7. Any other value will result in a CML fault and the write will be ignored. This command has one data byte. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |