| 数据搜索系统,热门电子元器件搜索 |
|
LTM4686BIVPBF 数据表(PDF) 103 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4686BIVPBF 数据表(HTML) 103 Page - Analog Devices |
|
103 / 130 page ![]() LTM4686B 103 Rev. 0 For more information www.analog.com APPENDIX C: PMBUS COMMAND DETAILS IOUT_OC_FAULT_RESPONSE The IOUT_OC_FAULT_RESPONSE command instructs the device on what action to take in response to an output overcurrent fault. The data byte is in the format given in Table 26. The device also: • Sets the IOUT_OC bit in the STATUS_BYTE • Sets the IOUT bit in the STATUS_WORD • Sets the IOUT Overcurrent Fault bit in the STATUS_IOUT command, and • Notifies the host by asserting ALERT pin, unless masked. This command has one data byte. Table 26. IOUT_OC_FAULT_RESPONSE Data Byte Contents BITS DESCRIPTION VALUE MEANING 7:6 Response For all values of bits [7:6], the LTM4686B: • Sets the corresponding fault bit in the status commands and • Notifies the host by asserting ALERT pin, unless masked. The fault bit, once set, is cleared only when one or more of the following events occurs: • The device receives a CLEAR_FAULTS command • The output is commanded through the RUNn pin, the OPERATION command, or the combined action of the RUNn pin and OPERATION command, to turn off and then to turn back on, or • Bias power is removed and reapplied to the LTM4686B. 00 The LTM4686B continues to operate indefinitely while maintaining the output current at the value set by IOUT_OC_ FAULT_LIMIT without regard to the output voltage (known as constant-current or brick-wall limiting). 01 Not supported. 10 The LTM4686B continues to operate, maintaining the output current at the value set by IOUT_OC_FAULT_LIMIT without regard to the output voltage, for the delay time set by bits [2:0]. If the device is still operating in current limit at the end of the delay time, the device responds as programmed by the Retry Setting in bits [5:3]. 11 The LTM4686B shuts down immediately and responds as programmed by the Retry Setting in bits [5:3]. 5:3 Retry Setting 000–110 The unit does not attempt to restart. The output remains disabled until the fault is cleared by cycling the RUNn pin or removing bias power. 111 The device attempts to restart continuously, without limitation, until it is commanded OFF (by the RUNn pin or OPERATION command or both), bias power is removed, or another fault condition causes the unit to shut down. Note: The retry interval is set by the MFR_RETRY_DELAY command. 2:0 Delay Time XXX The number of delay time units in 16ms increments. This delay time is used to determine the amount of time a unit is to continue operating after a fault is detected before shutting down. Only valid for deglitched off state. Fault Responses IC Temperature COMMAND NAME CMD CODE DESCRIPTION TYPE PAGED DATA FORMAT UNITS NVM DEFAULT VALUE MFR_OT_FAULT_RESPONSE 0xD6 Action to be taken by the device when an internal overtemperature fault is detected. R Byte N Reg 0xC0 |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |