LTM4686BIVPBF 数据表(PDF) 101 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4686BIVPBF 数据表(HTML) 101 Page - Analog Devices |
|
101 / 130 page ![]() LTM4686B 101 Rev. 0 For more information www.analog.com APPENDIX C: PMBUS COMMAND DETAILS Table 24. VOUT_OV_FAULT_RESPONSE Data Byte Contents BITS DESCRIPTION VALUE MEANING 7:6 Response For all values of bits [7:6], the LTM4686B: • Sets the corresponding fault bit in the status commands and • Notifies the host by asserting ALERT pin, unless masked. The fault bit, once set, is cleared only when one or more of the following events occurs: • The device receives a CLEAR_FAULTS command. • The output is commanded through the RUNn pin, the OPERATION command, or the combined action of the RUNn pin and OPERATION command, to turn off and then to turn back on, or • Bias power is removed and reapplied to the LTM4686B. 00 Part performs OV pull down only (i.e., turns off the top MOSFET and turns on lower MOSFET while VOUT is > VOUT_OV_FAULT) 01 The PMBus device continues operation for the delay time specified by bits [2:0] and the delay time unit specified for that particular fault. If the fault condition is still present at the end of the delay time, the unit responds as programmed in the Retry Setting (bits [5:3]). 10 The device shuts down immediately (disables the output) and responds according to the retry setting in bits [5:3]. 11 Not supported. Writing this value will generate a CML fault. 5:3 Retry Setting 000–110 The unit does not attempt to restart. The output remains disabled until the fault is cleared until the device is commanded OFF bias power is removed. 111 The PMBus device attempts to restart continuously, without limitation, until it is commanded OFF (by the RUNn pin or OPERATION command or both), bias power is removed, or another fault condition causes the unit to shut down without retry. Note: The retry interval is set by the MFR_RETRY_DELAY command. 2:0 Delay Time XXX The delay time in 10µs increments. This delay time determines how long the controller continues operating after a fault is detected. Only valid for deglitched off state VOUT_UV_FAULT_RESPONSE The VOUT_UV_FAULT_RESPONSE command instructs the device on what action to take in response to an output undervoltage fault. The data byte is in the format given in Table 25. The device also: • Sets the VOUT bit in the STATUS_WORD • Sets the VOUT undervoltage fault bit in the STATUS_VOUT command • Notifies the host by asserting ALERT pin, unless masked. The UV fault and warn are masked until the following criteria are achieved: 1) The TON_MAX_FAULT_LIMIT has been reached 2) The TON_DELAY sequence has completed 3) The TON_RISE sequence has completed 4) The VOUT_UV_FAULT_LIMIT threshold has been reached 5) The IOUT_OC_FAULT_LIMIT is not present The UV fault and warn are masked whenever the channel is not active. The UV fault and warn are masked during TON_RISE and TOFF_FALL sequencing. This command has one data byte. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |