| 数据搜索系统,热门电子元器件搜索 |
|
LTM4686BIVPBF 数据表(PDF) 25 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LTM4686BIVPBF 数据表(HTML) 25 Page - Analog Devices |
|
25 / 130 page ![]() LTM4686B 25 Rev. 0 For more information www.analog.com OPERATION n Input overvoltage fault threshold and response (VIN_ OV_FAULT_LIMIT, VIN_OV_FAULT_RESPONSE), based on the SVIN pin voltage. n Input undervoltage warning threshold (VIN_UV_ WARN_LIMIT) based on the SVIN pin voltage. n Module input overcurrent warning threshold (IIN_OC_WARN_LIMIT). The control IC within the LTM4686B module ceases switching action if control IC temperature exceeds 160°C (Note 12). The control IC resumes operation after a 10°C cool-down hysteresis. Note that these typical parameters are based on measurements in a lab oven and are not production tested. This overtemperature protection is intended to protect the device during momentary overload conditions. The maximum rated junction temperature will be exceeded when this protection is active. Continuous operation above the specified absolute maximum operat- ing junction temperature may impair device reliability or permanently damage the device. TIME-AVERAGED AND PEAK READBACK DATA Time-averaged telemetry readback data accessible via I2C communications follow: n Channel output current (READ_IOUTn) and peak observed value of READ_IOUTn (MFR_IOUT_PEAKn). n Channel output voltage (READ_VOUTn) and peak observed value of READ_VOUTn (MFR_VOUT_PEAKn). n Channel output power (READ_POUTn). n Channel input current (MFR_READ_IINn) and module input current (READ_IIN). n Channel temperatures (READ_TEMPERATURE_1n) and peak observed values of READ_TEMPERATURE_1n (MFR_TEMPERATURE_1_PEAKn). n Control IC temperature (READ_TEMPERATURE_2) and peak observed value (MFR_TEMPERATURE_2_PEAK). n Input voltage (READ_VIN), based on the voltage of the SVIN pin, and peak observed value of READ_VIN (MFR_VIN_PEAK). n Channel topside power MOSFET (MTn) duty cycle (READ_DUTY_CYCLEn). Digitized cyclical telemetry is available at a 10Hz update rate, typical. Through the use of the MFR_ADC_CONTROL command, some signals of interest can be digitized more frequently—up to a 125Hz update rate, typical. Availability of newly digitized telemetry data can be made known via the MFR_ADC_TELEMETRY_STATUS command. Peak observed values of telemetry readback data can be cleared with the MFR_CLEAR_PEAKS I2C command, provided the WRITE_PROTECT register value permits it. (Executing MFR_CLEAR_PEAKS can be performed regardless of the state of the WP pin.) Details on the LTM4686B’s Fault Log Feature follow: n Fault logging is enabled when MFR_CONFIG_ALL[7] = 1b. n A fault log is present in NVM when STATUS_MFR_ SPECIFICn[3]Reports “1b”, which is propagated to the MFR Bit (Bit 12) of the STATUS_WORD register. n Retrieving fault log data, if present, is performed with the MFR_FAULT_LOG command. 147 bytes of data are retrieved using the PMBus-defined variant to the SMBus block read protocol. n The fault log contents in NVM, if present, are cleared by executing the MFR_FAULT_LOG_CLEAR command. n The fault log will not be written if a fault log is already present in NVM. n The LTM4686B can be forced to write a fault log to its NVM by executing the MFR_FAULT_LOG_STORE command; the LTM4686B will behave as if a channel faulted off. Note the command is NACKed and a CML fault is reported if a fault log is already present at the time of executing MFR_FAULT_LOG_STORE. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |