| 数据搜索系统,热门电子元器件搜索 |
|
ZUSBOPTSC01ZAC 数据表(PDF) 130 Page - Zilog, Inc. |
|
|
|||||||||||||||||||||||||||||
ZUSBOPTSC01ZAC 数据表(HTML) 130 Page - Zilog, Inc. |
|
130 / 402 page ![]() General-Purpose Timer P R E L I M I N A R Y PS024604-1005 Z8 Encore!® Motor Control Flash MCUs Product Specification 108 Bit Position Value (H) Description [7] TEN 0 Timer Enable Timer is disabled. 1 Timer enabled. [6] TPOL Timer Input/Output Polarity This bit is a function of the current operating mode of the timer. It determines the polarity of the input and/or output signal. When the timer is disabled, the Timer Output signal is set to the value of this bit. ONE-SHOT mode–If the timer is enabled the Timer Output signal pulses (changes state) for one system clock cycle after timer Reload. CONTINUOUS mode–If the timer is enabled the Timer Output signal is complemented after timer Reload. COUNTER mode–If the timer is enabled the Timer Output signal is complemented after timer reload. 0 = Count occurs on the rising edge of the Timer Input signal. 1 = Count occurs on the falling edge of the Timer Input signal. PWM SINGLE OUTPUT mode–When enabled, the Timer Output is forced to TPOL after PWM count match and forced back to TPOL after Reload. CAPTURE mode–If the timer is enabled the Timer Output signal is complemented after timer Reload. 0 = Count is captured on the rising edge of the Timer Input signal. 1 = Count is captured on the falling edge of the Timer Input signal. COMPARE mode–The Timer Output signal is complemented after timer Reload. GATED mode–The Timer Output signal is complemented after timer Reload. 0 = Timer counts when the Timer Input signal is High and interrupts are generated on the falling edge of the Timer Input. 1 = Timer counts when the Timer Input signal is Low and interrupts are generated on the rising edge of the Timer Input. CAPTURE/COMPARE mode–If the timer is enabled, the Timer Output signal is complemented after timer Reload 0 = Counting starts on the first rising edge of the Timer Input signal. The current count is captured on subsequent rising edges of the Timer Input signal. 1 = Counting starts on the first falling edge of the Timer Input signal. The current count is captured on subsequent falling edges of the Timer Input signal. |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |