| 数据搜索系统,热门电子元器件搜索 |
|
PSD834210MIT 数据表(PDF) 56 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
PSD834210MIT 数据表(HTML) 56 Page - STMicroelectronics |
|
56 / 89 page ![]() PSD834F2V 56/89 Figure 29. APD Unit Automatic Power-down (APD) Unit and Power- down Mode. The APD Unit, shown in Figure 29, puts the PSD into Power-down mode by monitor- ing the activity of Address Strobe (ALE/AS, PD0). If the APD Unit is enabled, as soon as activity on Address Strobe (ALE/AS, PD0) stops, a four bit counter starts counting. If Address Strobe (ALE/ AS, PD0) remains inactive for fifteen clock periods of CLKIN (PD1), Power-down (PDN) goes High, and the PSD enters Power-down mode, as dis- cussed next. Table 27. Power-down Mode’s Effect on Ports Power-down Mode. By default, if you enable the APD Unit, Power-down mode is automatically en- abled. The device enters Power-down mode if Ad- dress Strobe (ALE/AS, PD0) remains inactive for fifteen periods of CLKIN (PD1). The following should be kept in mind when the PSD is in Power-down mode: s If Address Strobe (ALE/AS, PD0) starts pulsing again, the PSD returns to normal Operating mode. The PSD also returns to normal Operating mode if either PSD Chip Select Input (CSI, PD2) is Low or the Reset (RESET) input is High. s The MCU address/data bus is blocked from all memory and PLDs. s Various signals can be blocked (prior to Power- down mode) from entering the PLDs by setting the appropriate bits in the PMMR registers. The blocked signals include MCU control signals and the common CLKIN (PD1). Note that blocking CLKIN (PD1) from the PLDs does not block CLKIN (PD1) from the APD Unit. s All PSD memories enter Standby mode and are drawing standby current. However, the PLD and I/O ports blocks do not go into Standby Mode because you don’t want to have to wait for the logic and I/O to “wake-up” before their outputs can change. See Table 27 for Power-down mode effects on PSD ports. s Typical standby current is of the order of microamperes. These standby current values assume that there are no transitions on any PLD input. Table 28. PSD Timing and Stand-by Current during Power-down Mode Note: 1. Power-down does not affect the operation of the PLD. The PLD operation in this mode is based only on the Turbo bit. APD EN PMMR0 BIT 1=1 ALE RESET CSI CLKIN TRANSITION DETECTION EDGE DETECT APD COUNTER POWER DOWN (PDN) DISABLE BUS INTERFACE EEPROM SELECT FLASH SELECT SRAM SELECT PD CLR PD DISABLE FLASH/EEPROM/SRAM PLD SELECT AI02891 Port Function Pin Level MCU I/O No Change PLD Out No Change Address Out Undefined Data Port Tri-State Peripheral I/O Tri-State Mode PLD Propagation Delay Memory Access Time Access Recovery Time to Normal Access Typical Stand-by Current Power-down Normal tPD (Note 1) No Access tLVDV 25 µA (Note 2) |
|
链接网址 |
| ALLDATASHEET是否为您带来帮助? [ DONATE ] |
关于 Alldatasheet | 广告服务 | 联系我们 | 隐私政策 | 数据表链接 | 链接交换 | 制造商名单 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |